6
Installation
Environment
Before you install your DIVA scale keep in mind the following factors, which might have a negative influence
on the scale's operation:
Vibration diminishes the scale’s ability to measure accurately. Excessive vibration from equipment
such as conveyors can cause inaccurate and non-repeatable readings.
Be sure the scale is leveled properly.
Air currents can also diminish the scale’s performance. Avoid placing the scale in front of or directly
under air vents.
Other than items being weighed, keep the scale free from objects rubbing or pressing against the
platter.
Contents of Packaging
Package contents for all DIVA units include:
DIVA scale base
Operation Manual
Display Cable
Tower included and attachment hardware (The optional display may be packed separately)
Communication and Display cables (from scale to scanner)
Sealing Kit
Setup
1. Open the box, carefully remove the packing material, take all items out of the carton.
2. Attach the display as described below, depending on which version of scale you ordered:
For Price Computing Version:
A: Pull the connector of the cable through the holes of
the table surface and tower mounting bracket;
B: Put (2) screws through the (2) arch holes on the
bracket and (2) holes on the table surface;
C: Attach cover to the surface of table with (2) nuts.
D: Connect the cable to the connector at the bottom of
the tower display
E: Attach the base of the display to the mounting bracket
by insuring that the (2) pins on the bracket are
inserted in the holes of the base to attach the tower
and snap the tower into place.
Towe
r
Attachment Screws (2)
Connector of cable
Tower Mounting Bracke
t
Table surface
A
ttachment wing nuts (2)
for Attachment Screws
Pin attachment holes
Attachment pins (2)