METTLER TOLEDO DIVA Operation Manual Honeywell Stratos Series Scanners 72191203 (05/2012) 1.
INTRODUCTION This publication is solely as a guide for individuals who purchased the METTLER TOLEDO Diva scale.
Precautions READ this manual BEFORE operating or servicing this equipment. FOLLOW these instructions carefully. SAVE this manual for future reference. DO NOT allow untrained personnel to operate, clean, inspect, maintain, service, or tamper with this equipment. ALWAYS DISCONNECT this equipment from the power source before cleaning or performing maintenance. CALL METTLER TOLEDO for parts, information, and service. WARNING ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE THIS EQUIPMENT.
Contents INTRODUCTION ............................................................................................................................................................... 1 DIMENSIONS ..................................................................................................................................................................... 5 INSTALLATION.........................................................................................................................................
METTLER TOLEDO Introduction Please read this instruction manual carefully. Computing scales. This manual is intended for use with all Diva Weigh Only and Price The Diva scale is combined with a scanner for full featured Checkout applications. The Diva scale is a high precision weighing instrument. It is designed for applications where product is sold directly to customers and has to be approved by local Weights and Measures officials. All of our equipment is assembled, tested and packed with great care.
METTLER TOLEDO FOR YOUR NOTES: 2 DIVA Operation Manual
METTLER TOLEDO DIVA Operation Manual 3
METTLER TOLEDO 4 DIVA Operation Manual
METTLER TOLEDO Dimensions High tower version for Price Computing DIVA Operation Manual Short tower version for Weigh Only 5
METTLER TOLEDO Installation Environment Before you install your DIVA scale keep in mind the following factors, which might have a negative influence on the scale's operation: Vibration diminishes the scale’s ability to measure accurately. Excessive vibration from equipment such as conveyors can cause inaccurate and non-repeatable readings. Be sure the scale is leveled properly. Air currents can also diminish the scale’s performance. Avoid placing the scale in front of or directly under air vents.
METTLER TOLEDO For Weigh Only Version: The Weigh Only version comes with a tower mount. Assemble the Weight Only tower as is illustrated here: Display Display Cable Display Bracket Display Tower 2. Set the scale base on a sturdy, level surface. Level the scale by turning the adjustable feet on the bottom of the unit. Adjust the feet until the level bubble is in the center of the circle. Bubble indicator: Correct Wrong 3. Put the platter on top of the DIVA scale base. 4.
METTLER TOLEDO Display and Keyboard Display Price Computing Version: 8 DIVA Operation Manual
METTLER TOLEDO Weight Only Version: Keyboard Used to return the scale to gross zero if drifting should occur. Tare key.
METTLER TOLEDO Cursors NET Zero Lights when tare is entered. Lights when gross weight is zero.
METTLER TOLEDO Operations Weighing and Communication Place the item to be weighed on the platter, the weight will be displayed. Remote ASCII commands can control all other functions including data transfer, zero, and tare, depending on the protocol. Backlight function Diva is equipped with a backlight for the display. To switch on the backlight, press and hold the “ZERO” key for about 3 seconds until the backlight turns on. Use the same procedure to switch the backlight off.
METTLER TOLEDO Setup This mode allows an operator to change certain soft switches directly from the keyboard. Press and hold the key until “grP 1” and “CONF” is displayed. This will take about 8 seconds. The scale is configurable for your specific needs with a special interactive set up procedure. In order to access the various prompts, you must utilize the following keys during the scale setup mode. This key is used to confirm the choice and then go to the next step.
METTLER TOLEDO Setup Soft Switches Group.Step Function Possible Selections Group 1 1.3 Beeper ON - Scale will “beep” when a key is pressed. OFF - No sound is made when a key is pressed. 1.4 Zero Cursor ON – Display zero cursor. OFF – Disable zero cursor. 1.5 Decimal point ON - . OFF - , 2.4 Digital Filter Selection 0 - Minimal 1 – Low (Used for Normal use) 2 - Medium 3 – High (Used when there is lots of vibration) 2.7 Display (1 or 4 Line) 0 – None 1 – 1 Line 2 – 4 Line 2.
METTLER TOLEDO Group.Step Function Possible Selections Group 3 3.1 Baud rate 0 = 1200 1 = 2400 2 = 4800 3 = 9600 4 = 19200 5 = 38400 3.2 Parity 0 = None 1 = Even 2 = Odd 3.3 Data 0 = 7 data bit 1 = 8 data bit 3.4 Bit stop 0 = None 1 = 1 stop bit 2 = 2 stop bit Chose Protocol 0 = Disabled 1 = NCI-ECR (WO) 2 = (reserved) 3 = 8217 Mettler-Toledo (WO) 4 = 8213 Mettler-Toledo (WO) 5 = EPOS 1(WO) 6 = EPOS 2(WO) 7 = (reserved) 8 = Dialog 06 (PC) 3.
DIVA Operation Manual 4.2 Return to Zero 4.1 Weight Change Group 4 3.7 Intercharacter Delay 3.6 Protocol Options 3.5 Protocol 3.4 Stop Bit 3.3 Data Bits 3.2 Parity 3.1 Baud Rate Group 3 2.8 Display Update Rate 2.7 Display Type 2.4 Digital Filter Group 2 1.5 Decimal Point 1.4 Zero Cursor 1.3 Beeper Group 1 Function 0 0 0 0 0 1 (NCI) 1 1 (8bits) 0(none) 5 (38.4kb) 2 1 (1Line) 2 (Low) On (.
METTLER TOLEDO Appendix Errors The Diva will display an error message if a scale problem or incorrect keyboard entry is sensed. The error codes are: E 11 RAM error E 16 ROM error E 18 EEPROM error E 20 Calibration error Cycle power to the scale and restart calibration. E 28 Transmission Error Reset Scale nnnnnn In weight display Over capacity nnnnnn in total price display Over 9999.99 Remove weight from Platter, if that does not work try cycling the power to the scale.
METTLER TOLEDO Accessories CIMF Description 71208240 VIVA Wall Mount Display Accessory Call your local MT Sales Representative Weight Only Dual Display Kit DIVA Operation Manual Illustration 17
METTLER TOLEDO 1900 Polaris Parkway Columbus, Ohio 43240-2020 P/N: 72191203 METTLER TOLEDO® is a Trademark of Mettler-Toledo, LLC ©2012 Mettler-Toledo, LLC Printed in China