METROLOGIC INSTRUMENTS, INC.
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc.
TABLE OF CONTENTS Important Notes - Before You Start ...................................................................... 1 Scale Program Mode............................................................................................ 2 Scale/Load Cell Configuration Bar Codes Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms) .............................................. 5 Pole Display Configuration..................................................................
TABLE OF CONTENTS IT Retail................................................................................................ 27 IBM 3rd Generation 46xx ...................................................................... 28 IBM OEM Full Speed USB ................................................................... 29 Additional POS Data Formatting Full Speed USB Table Top/Handheld .................................................. 30 Special Function ACK .....................................................
IMPORTANT NOTES - BEFORE YOU START It is important to carefully read the notes marked with a symbol on the pages contained in this manual. Not all configuration codes are designed to be used for both a single and dual cable scanner/scale system. Many of the configuration bar codes require additional steps before the unit can be configured and placed into service. Most of the bar codes in this addendum were designed to be used with a Stratos model that includes a scale.
SCALE PROGRAM MODE The following steps are only required for the scale configuration bar codes located on pages 5 - 19 (bar codes beginning with 996). 1. Power down the scanner/scale. Then, temporarily remove the scale platter and place it in a safe location. Figure 1. 2. Cut and remove the security seal over the program/calibration switch cover. See Figure 2 below for seal location on the StratosE and the StratosH models. See Figure 3 on page 3 for the seal location on the StratosS.
SCALE PROGRAM MODE Figure 3. StratosS Calibration Seal and Switch Location 5. Disconnect the scale-to-host RS232 cable from the unit (dual cable interface only). Figure 4. Disconnect scale-to-host RS232 Cable 6. Reinstall the platter and connect AC power to the scanner. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should be located near the equipment and be easily accessible. Metrologic recommends using a switched AC outlet.
SCALE PROGRAM MODE 7. If the system is equipped with a remote scale display, it will read H - - -. 8. Use the vertical window to scan the desired scale configuration bar codes, located on pages 5 - 19. Figure 5. 9. Reconnect the scale-to-host RS232 cable to the scanner (dual cable interface only). Figure 6. 10. The scale must now be calibrated, tested and certified by local Weights and Measures authorities before it can be placed in service.
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms) The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Set the scale measuring range from 0.00 to 30.00 pounds. Scale = Pounds ³ 9 9 6 0 0 1 Scale = Kilograms ³ 9 9 6 0 0 Set the scale measuring range from 0.000 to 15.000 kilograms.
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale Has Display ³ 9 9 6 0 0 3 Set the scale to use a remote display to show all scale activity. A remote display must be plugged into the Scale RS485 to Display connector on the MS2xx0 (see Figure 7) for this feature to function properly.
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. The scale’s filter setting allows the unit to withstand a certain amount of vibration from the checkout counter. A stronger filter allows for more vibration to be absorbed but the weight may take a little longer to settle.
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Medium Filter ³ 9 9 6 0 0 6 Scale = Strong Filter ³ 8 9 9 6 0 0 Medium filter setting for moderate vibration environments. 7 Strong filter setting for high vibration environments.
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Scroll Weight Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. These bar codes only affect the pole display. Scale = Scroll Settling Weight ³ 9 9 6 0 1 0 Scale = Blank Non-Steady ³ 9 9 6 0 1 Scroll the weight on the display showing the weight as it changes.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Price Computing Configuration The following bar codes are only used when the scale is in Dual Cable mode. The MS2xx0 must be in scale program mode to use these bar codes. * Scale = No Price Computing ³ 9 9 6 0 0 8 Scale = Price Computing ³ 10 9 9 6 0 0 9 Scale is not the price computing type. * Factory Default Setting Scale is the price computing type.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes. Scale = EPOS Protocol Set the scale RS232 protocol to Serial EPOS.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes. Scale = NCI-ECR Protocol Set the scale RS232 protocol to NCI-ECR.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes. Scale = EMEA Special Configuration ³ 9 9 6 0 4 1 Set the scale to Avery EPOS protocol, kilograms, with a remote display, loose filter, no price computing, and scroll weight.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes.
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes.
SCALE/LOAD CELL CONFIGURATION BAR CODES Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication The MS2xx0 must be in scale program mode to use this bar code. If your application requires single cable communication, scan the following barcode to set the scale configuration to the single cable defaults as required by the scanner. Scale = Single Cable Interface ³ 9 9 6 0 1 Set the scale to communicate via the single-cable interface.
SCANNER CONFIGURATION BAR CODES Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode The following bar codes can be used to place, as well as configure, the scanner in Dual Cable mode. The MS2xx0 does not need to be in scale program mode to use the following bar codes. Scanner = Dual Cable Mode ³ 9 9 9 9 5 3 Places the scanner in Dual Cable mode. In a dual cable environment, the scanner and scale work independently.
SCANNER CONFIGURATION BAR CODES Dual Cable Scanner Configuration Bar Codes IBM 3rd Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. rd IBM 3 Generation Communication ³ 9 9 9 9 5 2 IBM OEM Full Speed USB Communication Defaults ³ 9 9 9 9 7 When scanned the Stratos will operate as a table top scanner only. Terminal configuration, IBM 4690.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility MSS Global The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility ISS45 The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility OPOS The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility Retailix/NCR The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility Retailix/OPOS The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility IT Retail The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility IBM 3rd Generation 46xx The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. rd IBM 3 Generation 46xx, English† ³ † 9 9 9 9 6 Scanner/Scale Single Cable † IBM 46xx , RS485, English (lbs.) 0 Terminal Configuration, IBM 4690.
SCANNER CONFIGURATION BAR CODES Single Cable Protocols for POS Compatibility IBM OEM Full Speed USB The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM OEM Full Speed USB, English ³ 9 9 9 9 6 2 IBM OEM Full Speed USB, Metric ³ 9 9 9 9 6 Table Top Scanner/Scale Single Cable, IBM OEM Full Speed USB, 4-Digit Weight Mode, English (lbs.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner 4B Handheld ³ 3 1 6 4 3 0 Scanner 4A Flatbed ³ 30 3 1 6 4 1 Full Speed USB interface to 4B00h handheld usage. 0 Full Speed USB interface to 4A00h table top usage.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner/Scale 4A/6E Table Top Full Speed USB interface to the 4A00h/6E00h table top scanner/scale usage. This option is only compatible with Stratos models that have a scale.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Special Function ACK The following codes do not require that the MS2xx0 to be in scale program mode. Enable Special Function ACK Answer ³ 1 4 1 7 1 Answer simple special functions with ACK.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Prefix/Suffix The following codes do not require that the MS2xx0 to be in scale program mode. Use Protocol Prefix/Suffix ³ 1 4 1 7 1 Add protocol prefixes and suffixes to the bar code.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting 3x-30 Acknowledge Responses The following codes do not require that the MS2xx0 to be in scale program mode. No 3x-30 Answer ³ 1 4 1 7 1 0 *3x-30 Answer ³ 34 1 4 1 7 0 This bar code will inhibit all ‘simple acknowledge’ (3x-30) answers to POS or OPOS commands. The scanner will answer all NCR and OPOS commands that require a 3x-30 acknowledgement.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func Ans 3x30 ³ 1 4 1 9 1 4 *Spec Func Ans Ack ³ 1 4 1 9 0 Answer Special Function commands in the 3x-30 format as opposed to the Ack / Nak which is the norm. 4 Answer Special Function commands in the Ack / Nak format.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting BCC in POS communications The following codes do not require that the MS2xx0 to be in scale program mode. Skip BCC in messages ³ 1 4 1 4 1 0 *Add BCC in messages ³ 36 1 4 1 4 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions.. 0 The scanner will expect and answer all messages with the Block Check Character included.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting 3 Scale Status Bytes The following codes do not require that the MS2xx0 to be in scale program mode. Enable 3 Scale Status Bytes ³ 1 2 4 8 1 Required for applications where the host system display is the primary scale display and there is no remote pole display connected directly to the scanner/scale unit.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Scale Options The following codes do not require that the MS2xx0 to be in scale program mode. 5-Digit Weight ³ 1 4 1 0 1 Sets the English Mode weight to 5-digits, as in xx.yyy pounds. 0 In order to work properly, this bar code must be scanned AFTER scanning one of the English configuration bar codes found on pages 22 - 29. Scan the No Scale bar code: 1. No Scale 2.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting Remote Display The following codes do not require that the MS2xx0 to be in scale program mode. No Remote Display ³ 1 4 0 9 0 2 Add remote display to the scanner’s memory. Remote Display ³ 1 4 0 9 1 When no remote display is installed, scan the No Remote Display bar code AFTER scanning one of the configuration bar codes found on pages 22 - 29 to remove the scale’s display from the scanner memory.
SCANNER CONFIGURATION BAR CODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Activate StratosSTATS ³ 9 9 7 0 1 7 This bar code sets: • StratosSTATS bar code data formatting active. • Bar code Attempt Interval to 0.5 seconds. • Time to find supplements (code 128) to 0.3 seconds. Use StratosSTATS monitor to test this output format. When used with a POS, it must have the capability to parse and recognize the additional data.
SCANNER CONFIGURATION BAR CODES Additional POS Related Functions Scanner Beep on Weight Sent The following codes do not require that the MS2xx0 to be in scale program mode. Beep on Weight ³ 1 4 1 9 1 Request scanner beep when a successful weight is sent. This code should only be used for ‘weight on demand’ applications. If used with periodic weight request applications, the beeper will be continuously active (ON). 7 *Disable Beep on Weight ³ 1 4 1 9 0 When no beep on weight is desired.
SCANNER CONFIGURATION BAR CODES Auxiliary Port StratosSCHOOL™ The following codes do not require that the MS2xx0 to be in scale program mode. Auxiliary History Report ³ 9 9 7 0 1 1 The Auxiliary port may be used to download or clear data to StratosSCHOOL™. The two commands that can be used are Upload Scanner Data and Clear Scanner Data within the Serial Program Interface box on the StratosSCHOOL™ screen. Auxiliary Program Cable (MLPN 57-57008x-N-3) is required for this feature.
SCANNER CONFIGURATION BAR CODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner The following codes do not require that the MS2xx0 to be in scale program mode. STEP 1 Use the Stratos to scan the following bar code. This bar code will configure the Stratos’ auxiliary port to accept a Metrologic scanner as the secondary scanner.
SCANNER CONFIGURATION BAR CODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner Configuration sequence continued from previous page.
SCANNER TEST BAR CODES Supplemental Tests Display Software Numbers The following codes do not require that the MS2xx0 to be in scale program mode. These codes are for test purposes only. The following code will display software #’s on the 2-digit diagnostic display. The lasers will be turned off while the numbers are being displayed. The first number is the main decode processor software number. The second number is the I/O processor’s software number.
NOTES
November 2006 Printed in the USA 00 - 02034D