MS2xxx Stratos® Series Configuration Addendum
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Table of Contents Important Notes Before You Start............................................................................................ 1 Scale Program Mode .......................................................................................... 3 Scale/Load Cell Configuration Bar Codes Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms) .............................................. 7 Pole Display Configuration ...............................................
Retalix / NCR ....................................................................................... 29 IT Retail ................................................................................................ 30 IBM Self Checkout System .................................................................. 31 Various RS232 Single Cable Codes .................................................... 32 rd IBM 3 Generation 46xx ......................................................................
EAS Bar Codes EAS Device Types ............................................................................... 63 EAS Timeout ........................................................................................ 66 EAS Connection ................................................................................... 71 Continuous Mode ................................................................................. 74 EAS Deactivation ..........................................................................
vi
Important Notes Before You Start It is important to read the text at the top of each page of bar codes. The text will provide important additional information about the restrictions and uses of the bar codes shown. Not all configuration codes are designed to be used for both a single and dual cable scanner/scale system. Many of the configuration bar codes require additional steps before the unit can be configured and placed into service.
2
Scale Program Mode The following steps are only required for the scale configuration bar codes located on pages 7 - 21 (bar codes beginning with 996.) 1. Power down the scanner/scale. Then, temporarily remove the scale platter and place it in a safe location. See caution on page 4. Figure 1. 2. Cut and remove the security seal over the program/calibration switch cover. See Figure 2 below for seal location on the StratosE and the StratosH models.
Figure 3. StratosS Calibration Seal and Switch Location 5. Disconnect the scale-to-host RS232 cable from the unit (dual cable interface only.) Figure 4. Disconnect scale-to-host RS232 Cable 6. Reinstall the platter and connect AC power to the scanner. Note: Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should be located near the equipment and be easily accessible. Honeywell recommends using a switched AC outlet.
7. If the system is equipped with a remote scale display, it will read H - - -. 8. Use the vertical window to scan the desired scale configuration bar codes, located on pages 7 - 21. Figure 5. 9. Reconnect the scale-to-host RS232 cable to the scanner (dual cable interface only.) Figure 6. 10. The scale must now be calibrated, tested and certified by local Weights and Measures authorities before it can be placed in service.
6
Scale/Load Cell Configuration Bar Codes Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms) The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Pounds ³ 9 9 6 0 0 1 Scale = Kilograms ³ Set the scale measuring range from 0.00 to 30.00 pounds. Set the scale measuring range from 0.000 to 15.000 kilograms.
Pole Display Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale Has Display ³ 9 9 6 0 0 3 Set the scale to use a remote display to show all scale activity. A remote display must be plugged into the Scale 46xx to Display connector on the MS2xx0 (see Figure 7) for this feature to function properly. Figure 7.
Scale Settling Filter Configuration The following bar code can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use this bar code. The scale’s filter setting allows the unit to withstand a certain amount of vibration from the checkout counter. A stronger filter allows for more vibration to be absorbed but the weight may take a little longer to settle. Scales are normally shipped with a loose filter.
Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Medium Filter ³ 9 9 6 0 0 6 Scale = Strong Filter ³ 10 Medium filter setting for moderate vibration environments. 9 9 6 0 0 7 Strong filter setting for high vibration environments.
Scroll Weight Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. These bar codes only affect the pole display. Scale = Scroll Settling Weight ³ 9 9 6 0 1 0 Scale = Blank Non-Steady ³ Scroll the weight on the display showing the weight as it changes. Blank the display weight as it changes. Display stable weights only.
Dual Cable Scale Configuration Bar Codes Price Computing Configuration The following bar codes are only used when the scale is in Dual Cable mode. The MS2xx0 must be in scale program mode to use these bar codes. * Scale = No Price Computing ³ 9 9 6 0 0 8 Scale = Price Computing ³ 12 9 9 6 0 0 9 Scale is not the price computing type. * Factory Default Setting Scale is the price computing type.
Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 23. The MS2xx0 must be in scale program mode to use these bar codes. Scale = EPOS Protocol Set the scale RS232 protocol to Serial EPOS. Communication Port Settings: • ³ 9 9 6 0 1 3 2400 Baud • 7 Data Bits • 1 Stop Bit • Even Parity Set the scale RS232 protocol to Modified Serial EPOS.
Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 23. The MS2xx0 must be in scale program mode to use these bar codes. Scale = NCI-ECR Protocol Set the scale RS232 protocol to NCI-ECR.
Scale Protocols The following bar code will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 23. The MS2xx0 must be in scale program mode to use this bar code. Scale = EMEA Special Configuration ³ 9 9 6 0 4 1 Set the scale to Avery EPOS protocol, kilograms, with a remote display, loose filter, no price computing, and scroll weight.
COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 13 or 15 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = 2400 Baud Rate ³ 9 9 6 0 1 7 Scale = 9600 Baud Rate ³ 16 Set the scale baud rate for dual cable applications to 2400 baud.
COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 13 or 15 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = 19200 Baud Rate ³ 9 9 6 0 1 9 Scale = 38400 Baud Rate ³ Set the scale baud rate for dual cable applications to 19200 baud.
COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 13 or 15 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = 7 Data Bits, Odd Parity ³ 9 9 6 0 2 1 Scale = 7 Data Bits, Even Parity ³ 18 Set the scale communication parameters to 7 data bits, odd parity.
COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 13 or 15 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = 8 Data Bits, No Parity ³ 9 9 6 0 2 3 Scale = Odd Parity ³ Set the scale communication parameters to 8 data bit, no parity.
COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 13 or 15 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Even Parity ³ 9 9 6 0 2 5 Scale = No Parity ³ 20 Set the scale communication to even parity. 9 9 6 0 2 6 Set the scale communication to no parity.
Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication The MS2xx0 must be in scale program mode to use this bar code. If your application requires single cable communication, scan the following bar code to set the scale configuration to the single cable defaults as required by the scanner. Scale = Single Cable Interface ³ Set the scale to communicate via the single-cable interface.
22
Scanner Configuration Bar Codes Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode The following bar codes can be used to place, as well as configure, the scanner in Dual Cable mode. The MS2xx0 does not need to be in scale program mode to use the following bar codes. Scanner = Dual Cable Mode ³ 9 9 9 9 5 3 Places the scanner in Dual Cable mode. In a dual cable environment, the scanner and scale work independently.
Various Dual Cable Scanner Mode The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
IBM 3rd Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. rd IBM 3 Generation Communication ³ 9 9 9 9 5 2 IBM OEM Full Speed USB Communication Defaults ³ When scanned the Stratos will operate as a table top scanner only. Terminal configuration, IBM 4690.OS terminal device group configuration screen select: #1 scanner or #3 scanner.
Single Cable Protocols for POS Compatibility MSS Global The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
ISS45 The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
OPOS The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
Retalix/NCR The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
IT Retail The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
IBM Self Checkout System The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
Various RS232 Single Cable Codes The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
IBM 3rd Generation 46xx The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. rd IBM 3 Generation 46xx, † English ³ † Scanner/Scale Single Cable † IBM 46xx , RS485, English (lbs.) 9 9 9 9 6 0 Terminal Configuration, IBM 4690.
IBM OEM Full Speed USB The following bar codes can be used to configure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. IBM OEM Full Speed USB, English ³ 9 9 9 9 6 2 IBM OEM Full Speed USB, Metric ³ 34 Table Top Scanner/Scale Single Cable, IBM OEM Full Speed USB, 4-Digit Weight Mode, English (lbs.
Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner 4B Handheld ³ 3 1 6 4 3 0 Scanner 4A Flatbed ³ Full Speed USB interface to 4B00h handheld usage. Full Speed USB interface to 4A00h table top usage.
Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner/Scale 4A/6E Table Top Full Speed USB interface to the 4A00h/6E00h table top scanner/scale usage. This option is only compatible with Stratos models that have a scale.
Special Function ACK The following codes do not require that the MS2xx0 to be in scale program mode. Enable Special Function ACK Answer ³ Answer simple special functions with ACK.
Prefix/Suffix The following codes do not require that the MS2xx0 to be in scale program mode. Use Protocol Prefix/Suffix ³ Add protocol prefixes and suffixes to the bar code.
3x-30 Acknowledge Responses The following codes do not require that the MS2xx0 to be in scale program mode. No 3x-30 Answer ³ 1 4 1 7 1 0 *3x-30 Answer ³ This bar code will inhibit all ‘simple acknowledge’ (3x-30) answers to POS or OPOS commands. 1 4 1 7 0 0 The scanner will answer all NCR and OPOS commands that require a 3x-30 acknowledgement.
Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func Ans 3x30 ³ 1 4 1 9 1 4 *Spec Func Ans Ack ³ 40 Answer Special Function commands in the 3x-30 format as opposed to the Ack / Nak which is the norm. 1 4 1 9 0 4 Answer Special Function commands in the Ack / Nak format.
Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func 30-30 Status Returns Special Function commands in the 30-30 status as opposed to the 33-30 status. Note: Requires ‘Spec Func Ans 3x-30’ on page 40 to be set. ³ 1 4 2 2 1 5 *No Spec Func 30-30 Status ³ 1 4 2 2 0 5 Disables redirection of Special Function 3x-30 status to 30-30 status.
Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Command Reject Answer ³ 1 4 2 1 1 7 *Send Command Reject Answer ³ 42 This bar code will ignore sending a command reject answer to the POS mode. 1 4 2 1 0 7 This bar code will send command reject answer to the POS if the command is rejected by the scanner.
Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Spec Func Answer ³ 1 4 2 1 1 6 *Spec Func Answer ³ This bar code will ignore sending a special function response answer in POS mode. 1 4 2 1 0 6 This bar code will send a special function response answer to the POS.
BCC in POS communications The following codes do not require that the MS2xx0 to be in scale program mode. Skip BCC in messages ³ 1 4 1 4 1 0 *Add BCC in messages ³ 44 This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions. 1 4 1 4 0 0 The scanner will expect and answer all messages with the Block Check Character included.
3 Scale Status Bytes The following codes do not require that the MS2xx0 to be in scale program mode. Enable 3 Scale Status Bytes ³ Required for applications where the host system display is the primary scale display and there is no remote pole display connected directly to the scanner/scale unit.
Scale Options The following codes do not require that the MS2xx0 to be in scale program mode. 5-Digit Weight ³ 1 4 1 0 1 0 Sets the English Mode weight to 5-digits, as in xx.yyy pounds. In order to work properly, this bar code must be scanned AFTER scanning one of the English configuration bar codes found on pages 26 - 34. Scan the No Scale bar code: 1. No Scale 2.
Remote Display The following codes do not require that the MS2xx0 to be in scale program mode. No Remote Display ³ 1 4 0 9 0 2 Remote Display ³ When no remote display is installed, scan the No Remote Display bar code AFTER scanning one of the configuration bar codes found on pages 26 - 34 to remove the scale’s display from the scanner memory. Add remote display to the scanner’s memory.
StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Activate StratosSTATS ³ 9 9 7 0 1 7 This bar code sets: • StratosSTATS bar code data formatting active. • Bar code Attempt Interval to 0.5 seconds. • Time to find supplements (code 128) to 0.3 seconds. Use StratosSTATS monitor to test this output format. When used with a POS, it must have the capability to parse and recognize the additional data.
StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a customer service representative. Dual Stats Xmit Allows non-RS232 interfaces transmit normally without StratosSTATS and concurrently RS232 interfaces transmit with StratosSTATS.
StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a customer service representative. Dual Xmit Carriage Return ³ 1 3 8 5 1 2 *No Dual Xmit Carriage Return ³ 50 This bar code enables a secondary carriage return suffix to be used only for the dual StratosSTATS RS232 transmission. 1 3 8 5 0 2 Resets StratsSTATS RS232 dual transmission suffix.
Additional POS Related Functions Scanner Beep on Weight Sent The following codes do not require that the MS2xx0 to be in scale program mode. Beep on Weight ³ 1 4 1 9 1 7 *Disable Beep on Weight ³ Request scanner beep when a successful weight is sent. This code should only be used for ‘weight on demand’ applications. If used with periodic weight request applications, the beeper will be continuously active (ON). 1 4 1 9 0 7 When no beep on weight is desired.
Restrict In-Store Codes The following codes do not require that the MS2xx0 to be in scale program mode. Restrict In-Store Codes This bar code places tighter restrictions on in-store codes. These codes are: EAN13 UPCA ³ 1 2 5 8 1 0 *No Restrict In-Store Codes ³ Sys2 Sys2 and Sys4 Disable restrictions on in-store codes.
Scale Shadow Mode The following codes do not require that the MS2xx0 to be in scale program mode. Scale Shadow Mode This bar code sets the scale to the highest priority to allow for frequent scale - POS commands. This bar code is only to be used in single cable scale mode. ³ 1 4 2 2 1 7 *No Scale Shadow Mode ³ Disables the Scale Shadow Mode.
Scanner Razz on Not-On-File The following codes do not require that the MS2xx0 to be in scale program mode. Razz on Not-On-File ³ 1 4 2 1 1 5 *Beep on Not-On-File ³ This bar code changes the audible to a razz signal when a Not-On-File command is received. This bar code restores the beep as the NotOn-File audible.
Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a customer service representative. *Horizontal High DOF ³ 2 1 8 7 0 2 Horizontal Medium DOF ³ This bar code sets the DOF for all horizontal laser channels to High DOF, which allows the farthest scanning. * Factory Default Setting This bar code sets the DOF for all horizontal laser channels to Medium DOF.
Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a customer service representative. Horizontal Close DOF ³ 2 1 8 7 2 2 Horizontal Ultra Close DOF ³ 56 This bar code sets the DOF for all horizontal laser channels to Close DOF. 2 1 8 7 3 2 This bar code sets the DOF for all horizontal laser channels to Ultra Close DOF.
Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a customer service representative. *Vertical High DOF ³ 2 1 8 7 0 0 Vertical Medium DOF ³ This bar code sets the DOF for the vertical laser channels to High DOF, which allows the farthest scanning. * Factory Default Setting This bar code sets the DOF for vertical laser channels to Medium DOF.
Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a customer service representative. Vertical Close DOF ³ 2 1 8 7 2 0 Vertical Ultra Close DOF ³ 58 This bar code sets the DOF for the vertical laser channels to Close DOF. 2 1 8 7 3 0 This bar code sets the DOF for vertical laser channels to Ultra Close DOF.
Auxiliary Port StratosSCHOOL™ The following codes do not require that the MS2xx0 to be in scale program mode. Auxiliary History Report ³ 9 9 7 0 1 1 The Auxiliary port may be used to download or clear data to StratosSCHOOL™. The two commands that can be used are Upload Scanner Data and Clear Scanner Data within the Serial Program Interface box on the StratosSCHOOL™ screen. Auxiliary Program Cable (PN 57-57008x-N-3) is required for this feature.
Quick Start for a Secondary Honeywell Scanner The following codes do not require that the MS2xx0 to be in scale program mode. Step 1 Use the Stratos to scan the following bar codes. These bar codes will configure the Stratos’ auxiliary port to accept a Honeywell scanner as the secondary scanner.
Step 2 Configure the secondary scanner to match the auxiliary port’s data format. Use the Secondary Scanner to scan the following bar codes in the order shown.
Quick Start for a Secondary Honeywell Scanner Configuration sequence continued from previous page.
EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. *No EAS Device ³ 3 3 7 2 0 No EAS device is connected.
EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode.
EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. *EAS Digital Aux Port ³ 1 4 6 1 0 0 EAS Digital Host Port ³ The EAS signals use the RTS and CTS line of the Auxiliary RS232 In connector. * Factory Default Setting The EAS signals use the RTS and CTS lines of the scanner RS232 to Host connector.
EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. EAS RS232 on Aux Port ³ 1 4 6 1 1 1 *No EAS RS232 on Aux Port ³ 72 This bar code allows the EAS RS232 signal to use the Tx Out and Rx In lines of the scanner to Aux RS232 In connector. 1 4 6 1 0 1 There is no EAS RS232 signal (Tx Out and Rx In) used on the scanner Aux RS232 In connector.
EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. EAS RS232 on Host Port ³ 1 4 6 1 1 2 *No EAS RS232 on Host Port ³ This bar code allows the EAS RS232 signal to use the Tx Out and Rx In lines of the scanner to Host RS232 In connector. 1 4 6 1 0 2 There is no EAS RS232 signal (Tx Out and Rx In) used on the scanner to Host RS232 In connector.
Continuous Mode The following codes do not require that the MS2xx0 to be in scale program mode. EAS Continuous Mode ³ 1 4 6 1 1 5 *EAS Interlock Mode ³ When in continuous mode and the scanner is enabled, the EAS will always be online to deactivate an EAS tag. This bar code establishes EAS is used in the Interlocked mode.
EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Blink Scan LED on Deactivation ³ 1 4 6 1 1 3 *No Blink LED on Deactivation ³ The scanner will blink the scan LED upon receipt of an EAS deactivate acknowledge signal. Do not blink the scan LED upon receipt of an EAS deactivate acknowledge signal.
EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Fast Beep on Deactivation ³ 1 4 6 1 1 4 *No Beep on Deactivation ³ 76 Fast beep the scanner’s beeper receipt of an EAS deactivate acknowledge signal. 1 4 6 1 0 4 Do not fast beep the scanner’s beeper receipt of an EAS deactivate acknowledge signal.
EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Volume Switch = Manual ³ 1 4 6 1 1 6 *Volume Switch = Normal ³ The volume switch is used for manual EAS deactivation. Volume switch is used for normal volume function.
Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode. The RS232 EAS cable must be connected to one of the RS232 scanner ports. EAS Function #3 ³ 9 9 8 0 6 7 EAS Function #2 ³ 78 For Sensormatic ScanMax Pro, get EAS’s hardware version, software version, and serial number and transmit the information over the current scanner interface.
Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode. The RS232 EAS cable must be connected to one of the RS232 scanner ports. EAS Function #1 ³ 9 9 8 0 6 5 ScanMax RS232 Defaults ³ For Sensormatic ScanMax Pro, get EAS’s deactivation count and transmit the information over the current scanner interface. For Sensormatic ScanMax Pro, RS232 default setup.
80
Scanner Test Bar Codes Supplemental Tests Display Software Numbers The following code does not require that the MS2xx0 to be in scale program mode. This code is for test purposes only. The following code will display software numbers on the 2-digit diagnostic display. The lasers will be turned off while the numbers are being displayed. The first number is the main decode processor software number. The second number is the I/O processor’s software number.
82
Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.
Honeywell Scanning & Mobility 9680 Old Bailes Road For Mill, SC 29707 www.honeywellaidc.