User`s manual
5. Place MS860 laser scanner in front of the base, connect the cable from scanner to COM1 of
the main system. Please note that COM1 on the system has been configured to supply +12V
on pin 9, thus eliminate the need for and extra power supply for the scanner. If COM2 needs
to be used for the scanner, jumpers in the system unit must be reconfigured to supply +12V
on COM2. In case a model of scanner which requires +5V is used instead, jumper in the
system unit must also be recofigured. Please refer to system unit's user's manual for the
settings.
6. Reassemble the scanner into the base and
secure with screws.
7 Secure the complete unit to the mounting
surface with four screws