User`s guide
2 - 21
ReM.config to install MBean and JRE for Genesis 7580 on RS232 using the Filter Driver:
<ReMConfig>
<ConfigurationData>
<MBeanType>FD</MBeanType>
<ScannerModel>MS7580</ScannerModel>
<Interface>RS232</Interface>
<PhysicalPort>1</PhysicalPort>
<VirtualPort>26</VirtualPort>
<JRE>jre-1_5_0_06.exe</JRE>
<Restart>no</Restart>
</ConfigurationData>
</ReMConfig>
ReM.config to use "AutoDetect" option that automatically detects scanner type in Licensing tool during
installation:
<ReMConfig>
<ConfigurationData>
<MBeanType>JPOS</MBeanType>
<ScannerModel>AutoDetect</ScannerModel>
<LogicalName>MS7580</LogicalName>
<Interface>RS232</Interface>
<PortNumber>1</PortNumber>
<USBSerial>no</USBSerial>
<ReMLicensing>
<FirmwareMainFile>AX000003EAA.fwz</FirmwareMainFile>
<LicenseFile>lic.txt</LicenseFile>
<UseGoldenSettings>no</UseGoldenSettings>
<FlashMainProcessor>yes</FlashMainProcessor>
<FlashCoProcessor>no</FlashCoProcessor>
<FlashCoProcessorBoot>no</FlashCoProcessorBoot>
</ReMLicensing>
<Restart>yes</Restart>
</ConfigurationData>
</ReMConfig>
Silent Uninstall
To uninstall the ReM client agent silently, use the uninstall-silent.bat file located in C:\Program
Files\JPOSScanner. This file will remove the client agent only. For Honeywell scanner models begin-
ning with IS or MS, this step is all that is required.
For other Honeywell models, you must also remove the Honeywell HHI DMAgent. To silently remove the
HHI DMAgent, execute the uninstall.bat file located in C:\Program Files\Honeywell\HHIDMA using
the /quiet parameter. For example: C:\Program Files\Honeywell\HHIDMA\uninstall.bat /quiet.