For safety reasons it is now checked whether the interface at the terminal is set correctly. At the
terminal open the menu and proceed as follows:
Press the keys ENTER <à> and <ESC> <//> simultaneously
- Language – English: <ENTER>
- Password: 00000 <ENTER>
- Change password – NO: <ENTER>
- Input of date/time: <ENTER>
- Texts/system programming: <ENTER>
- Change printer – NO: <ENTER>
- Change COM1 – NO: <ENTER>
- Enter the UST (UST is the ARCNET address of the PLC (Node)): 01 <ENTER>
- Step through the menu by pressing <ENTER> until the item
Konfiguration speichern is displayed. Set this parameter to YES and press <ENTER>
(See also planning manual SPSPlus Win – Transferring project data)
4.10. Connecting the programming cable to the basic unit and the PC
The programming cable 07 SK 90 connects the PLC to the PC. The 9-pole plug of this cable has to be
connected to COM1 of the 07 KT 9x. The other cable end has to be connected to the PC's serial interface (e.g.
COM1).
(See documentation 907 AC 1131 part 1, interface cable 07 SK 90.)
4.11. Copying the example program for the basic unit
Before copying the example program you have to make sure that the PLC is supplied with voltage, that the
programming cable is connected and that the PC is running. First, start the 907 AC 1131 programming software
on the PC. Then, continue as follows:
Open the example program "Barcodeleser_MT45ARCNET.pro" by selecting the menu item <File>
<Open>.
Prior to sending the example program to the basic unit, it has to be compiled. For that purpose
press <F11>.
Now the communication parameters have to be installed. Using the menu item <Online>
<Communication parameters> the corresponding interface parameters can be set. In our example
the driver ABB RS232 was installed on COM1 (19200 baud, no parity, 1 stop bit). If you are using
COM 2, only change the "Port" parameter.
In the menu <Online> <Login> you have to activate the sending process. Confirm the information
about the existing program stored on the PLC with <OK>.
Now you are asked "The program was changed! Do you want to load the new program?". Answer
this question with <Yes> to load the entire program.
For safety reasons the program has to be stored in the flash memory in case that a restart of the
system is required at a later time. For this, select the menu item <Online><Create boot project
(flash)>. Wait until the LED on the PLC stops flashing or the message 'FLASH' is no longer
displayed in the status bar at the bottom.
Finally, start the program by pressing <F5>.
The program is running.
(See documentation 907 AC 1131 part 2, software description, project management and general online
functions.)
The system is now ready for operation.
If you are using a terminal, please note the following:
FIf the error message at the MT45 does not disappear automatically, restart the complete system (disconnect
both devices from the supply voltage and then switch them on again). Then the error message at the MT45
disappears and the start page is called.