- METROLOGIC INSTRUMENTS Scanner Installation and User Guide Eclipse MS5100
10
AUDIBLE INDICATORS
When the MS5145 scanner is operatio nal, it provides audible feedback. T hese
sounds indicate the status of the scanner. Eight settings are availa ble for the
tone of the beep (normal, 6 alternate tones and n o tone). T o change the tone,
refer to the Configuration Guide.
One Beep – on power up
The green LED will turn on, then the red LED wil l flash and the
scanner will beep once. T he red LED will remain on for the
duration of the beep. The scanner is no w ready to scan.
One Beep – during operation
When the scanner successfully r eads a bar code, the red LED
will flash and the scanner will beep once (if programmed to do
so). If the scanner does not beep once and the red l ight does
not flash, then the bar code has not been successfull y read.
Three Beeps – during operation
When entering the program mode, the red LED will flash while
the scanner simultaneous l y beeps three times. The red LED
will continue to flash until the unit exits program mode. Upo n
exiting program mode, the scanner will beep three times and
the red LED will stop flashing.
When configured for communication time out, 3 bee ps during
operation will indicate that a communic ation timeout has
occurred.
Three Beeps – on power up
This is a failure indicator. Refer to the Failure Modes section
of this guide on page 11.
Razzberry Tone
This is a failure indicator or an invalid cod e read during
program mode. Refer to the Failure Modes section of this
guide on page 12.