867 pH Module Manual 8.867.
Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 867 pH Module Manual 8.867.8003EN 07.
Teachware Metrohm AG CH-9100 Herisau teachware@metrohm.com This documentation is protected by copyright. All rights reserved. Although all the information given in this documentation has been checked with great care, errors cannot be entirely excluded. Should you notice any mistakes please send us your comments using the address given above. Documentation in additional languages can be found on http://documents.metrohm.com.
■■■■■■■■■■■■■■■■■■■■■■ Table of contents Table of contents 1 Introduction 1 1.1 pH Module system ................................................................ 1 1.2 Instrument description ......................................................... 2 1.3 Measuring modes and commands ...................................... 2 1.4 About the documentation ................................................... 3 1.4.1 Symbols and conventions ........................................................ 3 1.
■■■■■■■■■■■■■■■■■■■■■■ Table of contents 4 Operation and maintenance 26 4.1 General notes ...................................................................... 26 4.1.1 Care ...................................................................................... 26 4.1.2 Maintenance by Metrohm Service .......................................... 26 4.2 Quality Management and qualification with Metrohm ............................................................................. 27 5 Troubleshooting 5.
■■■■■■■■■■■■■■■■■■■■■■ Table of figures Table of figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 867 pH Module 867 pH Module system ..................................................................... 1 Front 867 pH Module ........................................................................ 7 Rear of 867 pH Module ..............................................
■■■■■■■■■■■■■■■■■■■■■■ 1 Introduction 1 Introduction 1.1 pH Module system Tower-PC Touch Control Sensors USB Sample Processor Robotic Titrosampler Dosing Interface Relay Box Cond.
■■■■■■■■■■■■■■■■■■■■■■ 1.2 Instrument description 1.2 Instrument description The 867 pH Module has the following characteristics: ■ ■ ■ ■ ■ 1.3 Operation A touch-screen Touch Control or a high-performance PC software is used for operation. Dosing Dosinos and Dosimats can be used for dosing. Dosing is required for standard additions and when auxiliary solutions are to be dosed.
■■■■■■■■■■■■■■■■■■■■■■ 1 Introduction ■ ■ ■ ■ 1.4 STDADD The measuring modes for standard addition are listed separately only in tiamo™. In Touch Control they are integrated in the measuring mode MEAS Conc.
■■■■■■■■■■■■■■■■■■■■■■ 1.5 Safety instructions Instruction step Carry out these steps in the sequence shown. Method Dialog text, parameter in the software File ▶ New Menu or menu item [Next] Button or key WARNING This symbol draws attention to a possible life-threatening hazard or risk of injury. WARNING This symbol draws attention to a possible hazard due to electrical current. WARNING This symbol draws attention to a possible hazard due to heat or hot instrument parts.
■■■■■■■■■■■■■■■■■■■■■■ 1.5.2 1 Introduction Electrical safety The electrical safety when working with the instrument is ensured as part of the international standard IEC 61010. WARNING Only personnel qualified by Metrohm are authorized to carry out service work on electronic components. WARNING Never open the housing of the instrument. The instrument could be damaged by this. There is also a risk of serious injury if live components are touched.
■■■■■■■■■■■■■■■■■■■■■■ 1.5 Safety instructions 1.5.3 Working with liquids CAUTION Periodically check all system connections for leaks. Observe the relevant regulations in respect to working with flammable and/or toxic fluids and their disposal. 1.5.4 Recycling and disposal This product is covered by European Directive 2002/96/EC, WEEE – Waste from Electrical and Electronic Equipment. The correct disposal of your old equipment will help to prevent negative effects on the environment and public health.
■■■■■■■■■■■■■■■■■■■■■■ 2 Overview of the instrument 2 Overview of the instrument Figure 2 1 Front 867 pH Module "On" LED Lights up when the pH Module is ready for operation.
■■■■■■■■■■■■■■■■■■■■■■ Figure 3 Rear of 867 pH Module 1 Electrode connector (Ind.) For connecting pH, metal or ion-selective electrodes with integrated or separate reference electrode. Socket F. 2 Electrode connector (Ref.) For connecting reference electrodes, e.g. Ag/AgCl reference electrode. Socket B, 4 mm. 3 Temperature sensor connector (Temp.) For connecting temperature sensors (Pt1000 or NTC). Two B sockets, 2 mm. 4 Electrode connector (Pol.) For connecting polarizable electrodes, e.g.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation 3 Installation 3.1 Setting up the instrument 3.1.1 Packaging The instrument is supplied in highly protective special packaging together with the separately packed accessories. Keep this packaging, as only this ensures safe transportation of the instrument. 3.1.2 Checks Immediately after receipt, check whether the shipment has arrived complete and without damage by comparing it with the delivery note. 3.1.
■■■■■■■■■■■■■■■■■■■■■■ 3.2 Connecting a controller 3.2.1.1 Connecting a Touch Control NOTE The plug is protected against accidental disconnection of the cable by means of a pull-out protection feature. If you wish to pull out the plug, you will first need to pull back the outer plug sleeve marked with arrows. Connect the Touch Control as follows: 1 ■ Insert the plug of the Touch Control connection cable into the Controller socket.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation CAUTION The Touch Control must be shut down properly by deactivation with the power switch on the rear of the instrument before the power supply is interrupted. If this is not done, then there is a danger of data loss. Because of the fact that the power supply for the Touch Control is provided through the pH Module, you must never disconnect the pH Module from the power supply (e.g.
■■■■■■■■■■■■■■■■■■■■■■ 3.2 Connecting a controller Figure 5 Connecting the computer The instrument is recognized. Depending on the version of the Windows operating system used, the driver installation proceeds differently afterwards. Either the necessary driver software is installed automatically or an installation wizard is started. 3 Follow the instructions of the installation wizard.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation 1 Setting up the instrument ■ ■ Start the PC software. The instrument is automatically recognized. The configuration dialog for the instrument is displayed. Make configuration settings for the instrument and its connectors. More detailed information concerning the configuration of the instrument can be found in the documentation for the respective PC software. 3.3 Connecting MSB devices In order to connect MSB devices, e.g.
■■■■■■■■■■■■■■■■■■■■■■ 3.3 Connecting MSB devices NOTE When connecting MSB devices together, the following must be observed: ■ ■ Only one device of the same type can be used at a single MSB connector at one time. Type 700 Dosino and 685 Dosimat dosing devices cannot be connected together with other MSB instruments on a shared connector. These dosing devices must be connected separately. CAUTION Exit the control software before you plug in MSB instruments.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation Figure 7 3.3.2 Connecting a dosing device Connecting a stirrer or titration stand You can use the following instruments: ■ ■ With built-in magnetic stirrer (stirring "from below"): – 801 Stirrer – 803 Ti Stand Without built-in magnetic stirrer (stirring "from above"): – 804 Ti Stand with propeller stirrer 802 Stirrer Connect a stirrer or a titration stand as follows: 1 Connecting the stirrer or titration stand ■ ■ ■ ■ Exit the control software.
■■■■■■■■■■■■■■■■■■■■■■ 3.3 Connecting MSB devices Figure 9 3.3.3 Connecting the propeller stirrer to the titration stand Connecting a Remote Box Instruments that are controlled via remote lines and/or that send control signals via remote lines can be connected via the 6.2148.010 Remote Box. In addition to Metrohm, other instrument manufacturers also use similar connectors that make it possible to connect different instruments together.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation You can, for example, connect an 849 Level Control (fill level monitoring in a canister) or a 731 Relay Box (switch box for 230/110 volt alternating current sockets and low-voltage direct current outlets). The Remote Box also has an MSB socket at which a further MSB device, e.g. a dosing device or a stirrer, can be connected. You will find precise information concerning the pin assignment of the interface on the Remote Box in the appendix. 3.
■■■■■■■■■■■■■■■■■■■■■■ 3.4 Connecting USB devices 3 Switch on the Touch Control. The USB hub is recognized automatically. 3.4.3 Connecting a printer Printers that are connected to the 867 pH Module with Touch Control must meet the following requirements: ■ ■ ■ Printer languages: HP-PCL (PCL 3 to 5, PCL 3GUI), Canon BJL Commands or Epson ESC P/2 Printer resolution: 300 dots/inch or 360 dots/inch (Epson) Paper size: A4 or Letter, single-sheet feed.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation The following table offers an overview of the balances that you can use together with the 867 pH Module and of which cable you will need for connection to the RS-232 interface: Balance Cable AND ER, FR, FX with RS-232 interface (OP-03) 6.2125.020 + 6.2125.010 Mettler AB, AG, PR (LC-RS9) In the scope of delivery for the balance Mettler AM, PM, PE with interface option 016 6.2146.020 + 6.2125.
■■■■■■■■■■■■■■■■■■■■■■ 3.4 Connecting USB devices 2 Connect the RS-232 interface of the USB/RS-232 adapter with the RS-232 interface of the balance (see table for cable). 3 Switch on the Touch Control. 4 Switch on the balance. 5 Activate the RS-232 interface of the balance if necessary. 6 Configure the RS-232 interface of the USB/RS-232 adapter in the device manager of the Touch Control (see Touch Control manual). 3.4.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation The barcode reader is recognized automatically and entered in the device manager. 3 Configure the barcode reader in the device manager of the Touch Control (see Touch Control manual). Settings on the barcode reader: Program the barcode reader as follows (see also the manual for the barcode reader): 1 Switch the barcode reader to programming mode. 2 Specify the desired layout for the keyboard (USA, Germany, France, Spain, German-speaking Switzerland).
■■■■■■■■■■■■■■■■■■■■■■ 3.5 Connecting sensors 3.5 Connecting sensors The measuring interface contains the following measuring inputs: ■ ■ ■ ■ ■ 3.5.1 Ind. for a potentiometric electrode (pH, metal or ion-selective electrode) Ref. for a separate reference electrode Temp. for a temperature sensor (Pt1000 or NTC) Pol.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation Figure 13 3.5.3 Connecting a reference electrode Connecting a polarizable electrode Connect the polarizable electrode as follows: 1 Plug the electrode plug into the Pol. socket of the 867 pH Module. Figure 14 Connecting a polarizable electrode NOTE The electrode cable is protected against accidental disconnection of the cable by means of a pull-out protection. If you wish to pull out the plug again, you will first need to pull back the outer plug sleeve.
■■■■■■■■■■■■■■■■■■■■■■ 3.5 Connecting sensors 3.5.4 Connecting a temperature sensor or an electrode with integrated temperature sensor A temperature sensor of the Pt1000 or NTC type can be connected to the Temp. connector. Connect the temperature sensor or the electrode with integrated temperature sensor as follows: 1 Insert the plugs of the temperature sensor into the Temp. sockets of the pH Module.
■■■■■■■■■■■■■■■■■■■■■■ 3 Installation Figure 16 Connecting the iConnect The iConnect is detected automatically and entered as measuring input into the device properties of the pH Module. If an electrode is connected to the iConnect that is not yet included in the list of sensors for the control software, then a corresponding message will be displayed. The iConnect can be plugged in and unplugged while the pH Module is switched on.
■■■■■■■■■■■■■■■■■■■■■■ 4.1 General notes 4 Operation and maintenance 4.1 General notes 4.1.1 Care The 867 pH Module requires appropriate care. Excess contamination of the instrument may result in functional disruptions and a reduction in the lifetime of the otherwise sturdy mechanics and electronics. Spilled chemicals and solvents should be removed immediately. Above all, the plug connections on the rear of the instrument (in particular the power socket) should be protected from contamination.
■■■■■■■■■■■■■■■■■■■■■■ 4.2 4 Operation and maintenance Quality Management and qualification with Metrohm Quality management Metrohm offers you comprehensive support in implementing quality management measures for instruments and software. Further information on this can be found in the brochure "Metrohm Quality Management" available from your local Metrohm representative. Qualification Please contact your local Metrohm representative for support in qualification of instruments and software.
■■■■■■■■■■■■■■■■■■■■■■ 5.1 General 5 Troubleshooting 5.1 General Problem Cause Remedy The measured value is evidently wrong. The calibration is wrong. ■ ■ No or heavily fluctuating measuring signal. The measured value remains unstable and does not fulfil the drift criterion. 28 ■■■■■■■■ Check the calibration and repeat, if necessary. Check the buffer or standard solutions and repeat the calibration, if necessary. The manual temperature input is wrong. Enter the correct measuring temperature.
■■■■■■■■■■■■■■■■■■■■■■ Problem 5 Troubleshooting Cause Remedy The measuring chain is defective. Replace the measuring chain. Sluggish measured value setting. The pH or ISE membrane or the diaphragm is contaminated. Clean the membrane or the diaphragm. Insufficient slope during calibration. The pH or ISE membrane or the diaphragm is contaminated. Clean the membrane or the diaphragm. No hydrated layer is present on the glass membrane after measurements in water-free solutions.
■■■■■■■■■■■■■■■■■■■■■■ 6.1 Remote interface 6 Appendix 6.1 Remote interface The 6.2148.010 Remote Box allows devices to be controlled which cannot be connected directly to the MSB interface of the pH Module. 1 2 3 Figure 18 Connectors of the Remote Box 1 Cable For connecting to the pH Module. 3 Remote connector For connecting instruments with a remote interface. 6.1.1 2 MSB connector Metrohm Serial Bus. For connecting external dosing devices or stirrers.
■■■■■■■■■■■■■■■■■■■■■■ 6 Appendix Inputs +5 V approx. 50 kΩ Pull-up tp tp > 20 ms active = low, inactive = high Outputs Open Collector tp tp > 200 ms active = low, inactive = high IC = 20 mA, VCEO = 40 V +5 V: maximum load = 20 mA The following tables offer information concerning the assignment of the individual pins and their function: Table 1 867 pH Module Inputs and outputs of the remote interface Assignment Pin No.
■■■■■■■■■■■■■■■■■■■■■■ 6.1 Remote interface Assignment Pin No. Output 8 6 Output 9 7 Output 10 8 Output 11 13 Output 12 19 Output 13 20 0 volts / GND 14 +5 volts 15 0 volts / GND 25 Function* * Signal activated only for operation with Touch Control. Table 2 Explanation of the individual functions Function Explanation Start The current method is started at the time of activation. tpulse > 100 ms Stop The current method is canceled (Stop) at the time of activation.
■■■■■■■■■■■■■■■■■■■■■■ 867 pH Module 6 Appendix Function Explanation Warning The line is set for warning message display.
■■■■■■■■■■■■■■■■■■■■■■ 7.1 Measuring interface 7 Technical specifications 7.1 Measuring interface The 867 pH Module has one galvanically isolated measuring interface. The measuring cycle is 100 ms for all measuring modes. 7.1.1 Potentiometry One high-ohm measuring input (Ind.) for pH, metal or ion-selective electrodes and one measuring input (Ref.) for separate reference electrodes.
■■■■■■■■■■■■■■■■■■■■■■ 7.1.2 7 Technical specifications Temperature A measuring input (Temp.) for temperature sensors of the Pt1000 or NTC type with automatic temperature compensation. R (25 °C) and B value can be configured for NTC sensors. Measuring range Pt1000 –150 - +250 °C NTC –5 - +250 °C (R (25 °C) = 30,000 Ω and B (25/50) = 4,100 K) Resolution Pt1000 0.1 °C NTC 0.1 °C Measuring accuracy Pt1000 ±0.
■■■■■■■■■■■■■■■■■■■■■■ 7.2 Power connection Resolution 0.01 µA Measuring accuracy — 7.2 Power connection Supply voltage 100 - 240 V Frequency 50 - 60 Hz Power consumption 45 W Fuse 2 x 1.6 ATH 7.3 Safety specifications Design and testing ■ ■ ■ ■ Safety instructions 7.4 EN/IEC 61010-1 UL 61010-1 CSA-C22.2 No. 61010-1 Protection class I The documentation contains safety instructions which have to be followed by the user in order to ensure safe operation of the instrument.
■■■■■■■■■■■■■■■■■■■■■■ 7.5 7 Technical specifications Ambient temperature Nominal function range +5 - +45 °C (at a maximum of 85% humidity) Storage –20 - +60 °C Transport –40 - +60 °C 7.6 Reference conditions Ambient temperature +25 °C (± 3 °C) Relative humidity ≤ 60% Instrument status Instrument in operation at least 30 min Validity of the data After adjustment 7.7 Dimensions Width 142 mm Height 108 mm Depth 230 mm Weight 2,660 g Material Steel sheet 7.
■■■■■■■■■■■■■■■■■■■■■■ 7.8 Interfaces MSB connectors (Metrohm Serial Bus) Dosing device Connector for a maximum of four external dosing devices, models Dosimat or Dosino (MSB 1 to MSB 4). Stirrer Connector for a maximum of four stirrers. Stirrer control: switching on/off manually or coordinated with the titration sequence. Speed in 15 steps and shift direction can be selected. Remote Box Connector for a maximum of four Remote Boxes. Remote Boxes can be used to actuate and monitor external devices.
■■■■■■■■■■■■■■■■■■■■■■ 8 Warranty (guarantee) 8 Warranty (guarantee) Metrohm guarantees that the deliveries and services it provides are free of defects in materials, design or manufacturing. The general warranty period is 36 months (exclusions below) from the date of delivery or 18 months in the event of continuous operation. The warranty remains valid on the condition that the servicing is provided by a service organization authorized by Metrohm at defined intervals and with a defined scope.
■■■■■■■■■■■■■■■■■■■■■■ Deficiencies arising from circumstances that are not the responsibility of Metrohm, such as improper storage or improper use, etc., are expressly excluded from the warranty. Metrohm also offers a 120 month spare parts availability guarantee and a 60 month PC software support warranty, calculated from the date on which the product is withdrawn from the market.
■■■■■■■■■■■■■■■■■■■■■■ 9 Accessories 9 Accessories NOTE Subject to change without notice. 9.1 Scope of delivery 9.1.1 2.867.0010 Qty. 1 Order no. Description 1.867.0010 pH Module Module for pH/ion measurement as supplement to a Titrando or "stand-alone" in combination with a 900 Touch Control. 1 6.2103.130 Adapter red 2 mm plug / 4 mm socket For connecting plug B (4 mm) to 2 mm socket. 1 6.2103.140 Adapter black 2 mm plug / B socket 4 mm For connecting plug B (4 mm) to 2 mm socket.
■■■■■■■■■■■■■■■■■■■■■■ 9.1 Scope of delivery Qty. Order no. Description 1 6.2122.0x0 Power supply cable with IEC 60320 line socket, type C13 Cable plug according to customer requirements. Switzerland: SEV 1011, Type 12 6.2122.020 Germany, …: CEE 7, Type VII 6.2122.040 USA, …: NEMA 5-15, Type 498 6.2122.070 Length: 1.5 m 1 9.1.2 8.867.8003EN 867 pH Module Manual 2.867.0110 Order no. Description 1 1.854.0010 iConnect 1 1.867.0010 pH Module 1 1.900.0010 Touch Control 1 6.0278.
■■■■■■■■■■■■■■■■■■■■■■ Qty. Order no. 9 Accessories Description Internal reference electrode type: Diaphragm: Reference electrolyte type: Bridge electrolyte type: Electrolyte flow rate (μl/h): 1 6.2001.060 LL system Fixed ground-joint diaphragm c(KCl) = 3 mol/L c(KCl) = 3 mol/L 5 - 30 Support stand without support rod To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867. 1 6.2013.010 Clamping ring For support rods with a diameter of 10 mm.
■■■■■■■■■■■■■■■■■■■■■■ 9.1 Scope of delivery Qty. 1 Order no. Description 6.2021.020 Electrode holder Electrode holder for 4 electrodes and 2 buret tips Material: Plastic 1 6.2103.130 Adapter red 2 mm plug / 4 mm socket For connecting plug B (4 mm) to 2 mm socket. 1 6.2103.140 Adapter black 2 mm plug / B socket 4 mm For connecting plug B (4 mm) to 2 mm socket. 1 6.2307.230 Buffer solutions pH 4, 7 and 9 Mixed buffer solutions pH 4.00/7.00/9.
■■■■■■■■■■■■■■■■■■■■■■ Qty. 1 Order no. Description 6.2621.070 Hexagon key 5 mm 5 mm. Length (mm): 1 9 Accessories 6.2621.130 80 Hexagon key 2 mm 2 mm. 1 6.6064.010 USB Memory Stick for 900 Touch Control 1 6.2122.0x0 Power supply cable with IEC 60320 line socket, type C13 Cable plug according to customer requirements. Switzerland: SEV 1011, Type 12 6.2122.020 Germany, …: CEE 7, Type VII 6.2122.040 USA, …: NEMA 5-15, Type 498 6.2122.070 Length: 1.
■■■■■■■■■■■■■■■■■■■■■■ 9.1 Scope of delivery Qty. 1 9.1.3 Qty. Order no. Description 8.867.8003EN 867 pH Module Manual 2.867.0210 Order no. Description 1 1.854.0010 iConnect 1 1.867.0010 pH Module 1 6.0278.300 iUnitrode with Pt 1000 Combined pH glass electrode for measurements in difficult media, with memory chip for sensor data such as article and serial number, calibration data and calibration history.
■■■■■■■■■■■■■■■■■■■■■■ Qty. 1 9 Accessories Order no. Description 6.2001.060 Support stand without support rod To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867. 1 6.2013.010 Clamping ring For support rods with a diameter of 10 mm. Material: Metal Width (mm): 20 Height (mm): 16 1 6.2016.070 Support rod / 400 mm Material: Outer diameter (mm): Length (mm): 1 6.2021.
■■■■■■■■■■■■■■■■■■■■■■ 9.1 Scope of delivery Qty. 1 Order no. Description 6.2103.130 Adapter red 2 mm plug / 4 mm socket For connecting plug B (4 mm) to 2 mm socket. 1 6.2103.140 Adapter black 2 mm plug / B socket 4 mm For connecting plug B (4 mm) to 2 mm socket. 1 6.2151.000 Cable USB A – mini-DIN 8-pin Controller cable Length (m): 1 6.2307.230 1.8 Buffer solutions pH 4, 7 and 9 Mixed buffer solutions pH 4.00/7.00/9.
■■■■■■■■■■■■■■■■■■■■■■ Qty. 1 Order no. Description 6.2621.070 Hexagon key 5 mm 5 mm. Length (mm): 1 9 Accessories 6.2621.130 80 Hexagon key 2 mm 2 mm. 1 6.6056.231 tiamo ™ 2.3 Light CD: 1 license tiamo ™ 2.3 light computer program for controlling a titration system.
9.2 Optional accessories 9.2 ■■■■■■■■■■■■■■■■■■■■■■ Optional accessories Order no. Description 2.801.0010 801 Stirrer Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus). 2.802.0040 802 Stirrer (propeller stirrer) for 804 Ti Stand Rod stirrer with 6.1909.010 Propeller stirrer.
■■■■■■■■■■■■■■■■■■■■■■ Order no. Description 2.804.0010 804 Ti Stand without stand rod 9 Accessories Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand. 2.814.0010 814 USB Sample Processor (1T/1P) USB Sample Processor with one work station and one membrane pump for automatic processing of small to medium numbers of routine samples.
9.2 Optional accessories Order no. Description 2.814.0020 814 USB Sample Processor (1T/2P) ■■■■■■■■■■■■■■■■■■■■■■ USB Sample Processor with one work station and two membrane pumps for automatic processing of small to medium numbers of routine samples. The device can be controlled in «stand alone» operation using the Touch Control unit or by means of a PC with either the titration software tiamo™ or the chromatography software MagIC Net™. 2.814.
■■■■■■■■■■■■■■■■■■■■■■ 9 Accessories Order no. Description 6.2151.000 Cable USB A – mini-DIN 8-pin Controller cable Length (m): 867 pH Module 1.
■■■■■■■■■■■■■■■■■■■■■■ Index Index Numbers/Symbols 6.2151.000 controller cable ..... 11 685 Dosimat ............................ 14 700 Dosino .............................. 14 800 Dosino .............................. 14 801 Stirrer ................................ 15 803 Ti Stand ............................. 15 804 Ti Stand ............................. 15 805 Dosimat ............................ 14 A ADD ........................................... 3 B Balance ....................................
■■■■■■■■■■■■■■■■■■■■■■ V Validation ................................. 27 867 pH Module Index W Warranty ..................................