Owner manual
4 Introduction to the operation
746 VA Trace Analyzer / 747 VA Stand
4-48
• Shortly after the start of the determination, the prompt to add 10 mL of
calibration solution Pb-1 to the measuring vessel appears on the
screen:
5
Addition of 1
st
calibration solution
• Remove stopper 2525 and use a pipette to add 10 mL of calibration
solution Pb-1 with a mass concentration of 2.5 µµg/L to the measuring
vessel through the pipetting opening. Press the <ENTER> key.
• The screen shows the prompt to add 1 mL acetate buffer to the measur-
ing vessel:
6
Addition of acetate buffer
• Use a pipette to add 1 mL acetate buffer (1 mol/L, pH 4.6) to the
measuring vessel through the pipetting opening. Then close the pipet-
ting opening using stopper 2525 and press the <ENTER> key.
• The screen shows the prompt to add 100 µL of the solution CdRefSol
with the internal standard to the measuring vessel:
7
Addition of the internal standard
• Use a pipette to add 100 µµL of the cadmium standard solution with a
mass concentration of 1 mg/L to the measuring vessel through the pi-
petting opening. Then close the pipetting opening using stopper 2525 and
press the <ENTER> key.
8
Measurement of the 1
st
calibration solution
• Measurement of the 1
st
calibration runs as follows (see also section
4.4.3):
− Purging and stirring for 180 s.
− Call-up of the segment DPASV for measured value recording.
Lead and cadmium are enriched with stirring at the hanging mer-
cury drop at a measurement voltage of –800 mV and then deter-
mined anodically without stirring from –800 ... –200 mV. The se-
lected measurement mode DP leads to a current peak for lead
whose maximum lies at ca. –400 mV and a current peak for cad-
mium with a maximum at ca. –580 mV.
− The DPASV segment is then repeated twice. Both the three single
measurements for the substance lead and also the three single
ÚÚÄÄÄÄÄÄ
MEAS.TASK MESSAGE
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿¿
³³
³³
³³
CSOLN Pb-1 10.000 mL > M
³³
³³
³³
ÀÀÄÄÄÄÄÄ <Enter>: continue ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙÙ
ÚÚÄÄÄÄÄÄ
MEAS.TASK MESSAGE
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿¿
³³
³³
³³
DOS Acetate 1.000 mL > M
press <Esc> to break
³³
³³
³³
ÀÀÄÄÄÄÄÄ <Enter>: continue ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙÙ
ÚÚÄÄÄÄÄÄ
MEAS.TASK MESSAGE
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿¿
³³
³³
³³
ADD CdRefSol 100.000 uL > M
press <Esc> to break
³³
³³
³³
ÀÀÄÄÄÄÄÄ <Enter>: continue ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙÙ