Minimum clearances
All Metro wood res comply with AS/NZS 2918:2001. Minimum
clearances shown below are detailed in millimetres,
with a Pioneer double ue shield tted to the appliance
.
Measurements are taken from the following reference points
as illustrated:
- From the nearest combustible wall or surface
(A, B, D, E, G, H)
- From the Metro’s ue centre (A, B, C, D)
- From the outermost point of the Metro’s cabinet
construction (E, F, G, H)
- To the edge of the ash oor protectors non-combustible
surface (C, F, I, J, K, L, M)
AS/NZS 2918:2001 allows for a reduction in minimum clearances
as detailed in Section 3, tables 3.1 and 3.2 of the standard.
Some Metro models have undergone additional testing which
allows for reduced clearances. Please see the footnotes
below the tables for applicable models.
Specications were correct at the time of printing, but may
alter and those detailed within should be used only as a
guide. If in doubt, please consult your Metro retailer.
Wetback connections
Connections below are taken facing the Metro/wall.
• Tiny models are 92mm left of the ue centre.
• The Wee Rad is 226mm left of the ue centre.
• Xtreme models are 275mm left of the ue centre.
• All other models are 140mm left of the ue centre.
Clearance chart
N
O
Metro clearances and specications (Minimum clearances shown are in mm, with a Pioneer double ue shield tted)
Minimum installation clearances with a Pioneer double flueshield fitted (mm) Wetback Dimensions
Clean Air Models A B C D E F G H I J K L M N O
Width Depth Height
ECO Tiny Ped 210 430 580 290 25 200 185 60 790 650 990 875 250 280 470 490 530 665
ECO Tiny Rad 225 552 580 420 150 200 300 75 805 650 1165 925 250 280 470 505 530 665
R1 243 774 586 554 280 244 530 100 829 825 1370 1118 425 N/A N/A 488 485 668
R2 246 858 626 582 275 235 570 100 872 905 1449 1203 505 N/A N/A 575 537 690
Wee Rad
1
243 568 580 455 150 230 260 100 823 825 1224 1015 425 295 485 615 498 688
ECO Wee Ped 260 595 580 385 85 200 300 110 840 825 1120 950 425 295 485 590 530 665
ECO Wee Curve DV 300 555 580 405 100 200 250 150 880 825 1150 975 425 280 470 607 537 665
Xtreme Ped 251 624 630 441 110 227 280 100 881 907 1254 1065 507 349 539 688 554 721
Xtreme Rad - Legs 251 650 630 458 100 227 280 100 881 907 1277 1077 507 349 539 740 554 743
Xtreme Rad - Base 251 650 630 458 100 227 280 100 881 907 1277 1077 507 349 539 740 554 743
ECO Euro Rad DV 250 625 625 435 80 200 250 100 875 905 1240 1065 505 338 528 750 575 745
ECO Euro Ped DV
2
230 585 625 495 170 200 250 80 855 905 1325 1120 505 325 515 670 575 715
1
Wee Rad corner clearance (E) can be reduced to 120mm with the Wee Rad corner wing shields fitted. This in turn also reduces clearances (D) to
425mm, (K) to 1180mm and (L) to 985mm. When fitting the corner wing shields the Wee Rad itself must be installed to a corner clearance (E) of 120mm.
The corner wing shields are then fitted which gives a wall to shield corner clearance of 100mm.
2
ECO Euro Ped corner clearance (E) can be reduced to 110mm if installed with a Pioneer double flue shield with the side extensions fitted. This in turn also
reduces clearances (D) to 435mm, (K) to 1240mm and (L) to 1060mm.