Specifications
4
The ECO Euro Ped, ECO Wee Curve and ECO Euro Rad models 
have the option to be installed as “Direct Vent” appliances, 
thereby drawing all primary and secondary combustion air 
from outside the home. Once connected, this direct venting 
option ensures the air that is heated within the home, stays in 
the home improving efciency and reducing fuel usage.
Note: Connection of the Metro’s direct vent inlet to outside the home 
is optional. If not connected these Direct Vent models still offer greatly 
improved performance and lower emissions due to the unique pre-
heated air path for all primary and secondary combustion air that 
these models consume.
Direct Vent Options
Three “Direct Vent kits” are available to connect the ECO DV 
Metro to an air supply from outside the living environment of 
the home. The kits available include;
•  DV WALL KIT – For installations when the Metro is installed 
against an outside wall.
•  DV FLOOR KIT– For installations onto a oor which has a free 
air supply below it.
•  DV CEILING KIT– For installations when the Metro is installed 
against an internal wall and on a concrete oor
(DV Ceiling kit goes into the wall cavity, then up inside the wall into 
the ceiling cavity, where the air supply is drawn from)
Installing the Direct Vent Option
Remove the rear heatshield from the Metro wood re by 
unscrewing the four self tapping screws illustrated in Diagram 
3 and proceed as follows;
1.  Remove the section of panel illustrated with a “hatch”, from 
the mid/bottom section of the rear heatshield. This section 
to be removed has been pre-punched and only requires a 
few small tabs to be cut.
2. Take the “inlet spigot” supplied in the “Direct Vent kit” and 
slide it fully down into position into the brackets provided 
on the rear of the rebox.
3. Replace the Metro’s rear heatshield with the four screws 
previously removed.
The Metro wood re is now ready for installation once you have 
pre-tted the Direct Vent kit into the wall or oor. Full instructions 
for this procedure are supplied with the Direct Vent kits.
Inlet spigot
Rear 
heat shield
Diagram 3
Direct vent option