Specifications
35
Installation Guide
If you remove the card and insert a new card into its slot, one
of the following occurs:
1. If the part number and hardware switch settings match, the
software switch settings stay the same.
2. If the part number matches but the hardware switch
settings do not, the new hardware switch settings take
precedence. All other software settings remain unchanged.
3. If the part number does not match, all hardware settings
for the new card take precedence and the persistence file
is updated with the new data.
Upgrade Procedures
There are several ways of upgrading the embedded code
1
.
This section describes three methods to upgrade the
software.
• Command Line Interface (CLI) via FTP
• BOOT Process (to execute embedded software that does
not reside on the management card, or to transfer
embedded software to the management card via TFTP)
• NetBeacon Management Software
Metrobility does not support storing more than two copies of
corepm.biz. If the Flash File System (FFS) is full, we cannot
guarantee operation. In some instances, a full file system can
corrupt the FFS. If the file system’s limit is approached, a
warning message will appear on the console asking you to
delete unnecessary files.
1.When upgrading software to management cards in a stack, make sure that the same soft-
ware version is installed within that stack (e.g., version 3.1 code cannot be mixed with 3.0.1
code in the same stack).