Specifications
Command Line Interface
30
in the example below. Please refer to your modem’s manual
for compatible AT commands.
Modem
Configuration
The modem configuration information shown below is for a
Zoom/Fax Modem V.34X+ Model 2836.
E0 Disable echo.
N1 Enable automode detection.
Q1 Disable result codes to the DTE (data-terminal
equipment).
X0 Disable monitoring of busy tones.
&C0 RLSD (received line signal detector) remains ON at
all times.
&D0 Ignore DTR (data terminal ready); must also set &Q5.
&K0 Disable flow control.
&Q5 Modem will try to negotiate an error-corrected link.
&R1 CTS (clear to send) is always ON; RTS (ready to
send) is ignored.
&S1 DSR (data set ready) becomes active after answer
tone is detected, and inactive if carrier is lost.
&T5 Disable digital loopback.
&X0 Select internal timing.
S00 Set this to the number of rings for auto-answer;
number must be greater than zero.
Console Port
Configuration
The console port on the management card does not use
hardware control lines, nor does it support software flow control.
The port is permanently set to the following configuration: