Specifications

19
Installation Guide
The following is an example of the console display infor-
mation:
Metrobility Optical Systems Inc. Boot Application : 3.8.0
Executing Power-On Selftest.....
———————————————————————————
NETWORK INTERFACE PARAMETERS:
LAN IP address will be obtained from BOOTP
HARDWARE PARAMETERS:
Serial channels will use a baud rate of 9600
HARDWARE PARAMETERS:
R502-M Mpc850 (Rev 0.1) CPU running at 50 Mhz with 10 Mhz
input clock
DRAM 32 Mbytes
NVRAM 8 Kbytes
FLASH 8 Mbytes
This board’s Primary Ethernet MAC address is 0:0:0:0:0:0
The Primary Ethernet port will run in Half duplex mode
The board’s Secondary Ethernet MAC address is 0:0:0:0:0:0
The Secondary Ethernet port will run in Half duplex mode
M7500 BOOTLOADER PARAMETERS:
Chassis is not in a Stack
Name of the Boot image is boot.bin
Boot via the DISK Bootloader
Disk device type is FLASH
ID of the disk to be used is 0
Volume is pHILE formatted
The file to load and start is corepm.biz
RADIUS authentication for the console is not disabled.
RADIUS failure defaults to local authentication is not enabled
Error ER
ON
(steady)
Diagnostic or boot failure
ON
(blinking)
Performing diagnostics or
initializing system
OFF Normal operation
LED Name
Label Status Indication