Specifications
113
Admin Privilege Commands
Command: set
port fefenable
Description: Set the Far End Fault on an R133-xx port. This
allows the locally managed card to detect a
break in the remote card’s fiber port receiver.
Syntax: set port fefenable <chassis> <module> <port>
<enable | disable>
Note: To function properly, the Far End Fault setting
must be the same on both the local and remote
cards. Far End Fault is not applicable to the
copper port.
Example: Console> set port fefenable 2 6 2 enable
Far End Fault Enable successfully set.
Command: set
port help
Description: Show ‘set port’ subcommands.
Syntax: set port help
Example: Console>set port help
Command Description
————— ————————————
autoneg : Autonegotiation of duplex and/or speed.
bandwidth : Provision bandwidth (1Mb increments).
bert : Transmit BERT511 on TDM port.
burstlength : Burst at line rate for specified buffer
size.
disable : Disable port.
dislbkres : Disable loopback response when
requested from remote port.
duplex : Set port transmission to full or half
duplex.
enable : Enable port.
fault : Far End Fault generation when receive
fiber fails (ALC and TDM).
fefenable : Far End Fault generation when receive
fiber fails.
help : Show this message.
linebuildout : Copper port line length (T1/E1).
linecode : Set port linecode.
llr : Set port link loss return.