User guide

24 User Guide
Technical Specifications
Data Rate
Full duplex ______________________________________________1000Mbps
Power Requirements
R752-11 ______________________________________ 5V DC @ 1.4A, 7.0W
R752-1S ______________________________________ 5V DC @ 1.1A, 5.5W
R752-SS _____________________________________ 5V DC @ 0.84A, 4.2W
Environmental
Operating Temperature _____________________________________ 0 to 50° C
Storage Temperature _____________________________________ -30 to 70° C
Operating Humidity _________________________ 5% to 95% non-condensing
Weight_______________________________________________ 5 oz (0.14 kg)
Twisted-Pair Interface
Connector __________________________________ Shielded RJ-45, 8-pin jack
Impedance__________________________________________ 50 ohms typical
Signal Level Output (differential) _________________________ 0.95 to 1.05V
Signal Level Input _________________________________ 200 mV minimum
Supported Link Length _________________________________________100m
Cable Type ________________________________________ Category 5e UTP
tuoyaLniP54-JR
#niPlangiS
1+AD_IB
2-AD_IB
3+BD_IB
4+CD_IB
5-CD_IB
6-BD_IB
7+DD_IB
8-DD_IB
Multimode Fiber Optic Plug-in (O211-M5)
Connector _____________________________________________________LC
Wavelength _________________________________________________850nm
RX Input Sensitivity ________________________________ -19 dBm to 0 dBm
Output Power ____________________________________ -9 dBm to -3.5 dBm
Typical Link Budget _________________________________________ 16 dBm
Supported Link Length _________up to 550m (50/125 µm); or 275 m (62.5 µm)
Cable Type ________________ 50/125 or 62.5/125 µm multimode or 9/125 µm