User guide
12 Installation Guide
Boot the Management Card
Management of the Premise Service Platform is provided through a
local console, Metrobility’s NetBeacon or WebBeacon software, or any
SNMP network management application via a PC. WebBeacon is
embedded in the management card. SNMP is supported on many
general network platforms: SunNet Manager, HP OpenView for UNIX,
HP OpenView for NT, SNMPc and others.
Following power-up of the platform, the boot image is automatically
executed. It starts by performing a system initialization, followed by
diagnostic tests. During this process, the RUN LED will be off and the
ERROR LED will blink. After diagnostics are complete, if a failure has
occurred, the ERROR LED will remain on. The RUN LED will not be
lit until the operating system has started successfully.
The PC terminal session parameters for the management card are as
follows:
9600 Baud / 8 data bits / 1 stop bit / no parity / no flow control
Refer to the Command Line Interface Reference Guide for a detailed
description of how to boot for SNMP management and a complete
listing of configuration commands.
7