- RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT Installation & User Guide Models: RA21-13 / RA21-14 / RA21-15 / RA21-16 / RA21-17 / RA21-1J / RA21-1X / RA21-1Y
16 User Guide
Singlemode Fiber Optic Power Monitors
Through software
*
, you can read the input and output power levels of the
singlemode fiber optic port on the Access ONU.
Input Power Level
The accuracy of the input power monitor is ±1dBm from -28dBm to -12dBm.
The accuracy is ±2dBm from -31dBm to -29dBm. The monitor is unresponsive
below -31dBm. If there are no cables connected to the fiber port, the software
may display a reading of -40dBm. The Access ONU peaks at -12dBm and
reaches saturation at -7dBm.
The singlemode long haul (RA21-17) and extended long haul (RA21-1J) ports
are operational down to -34dBm, which is too low for the monitor to measure. If
the input power level is between -34dBm and -29dBm, a valid link will be
established, however, the light level displayed by the software will show a
reading of -40dBm. This reading is not a failure indication; it simply means the
level is beyond the range of the power monitor.
rotinoMrewoPtupnI
#ledoM
lanoitarepO
egnaR
etaruccA
gnirotinoM
egnaR
sdlohserhTparTgnidaeReruliaF
41-12AR
61-12AR
mBd7-ot92-mBd21-ot82-mBd7-dnamBd82-mBd13-
71-12AR
J1-12AR
mBd7-ot43-mBd21-ot13-mBd7-dnamBd13-mBd04-
Output Power Level
The accuracy of the output power monitor is ±3dBm. Failure readings indicate
that the unit is non-functional and must be replaced. If there are no cables
connected to the fiber port, the software may display readings that indicate
failure.
rotinoMrewoPtuptuO
#ledoM
lanoitarepO
egnaR
lacipyT
gnidaeR
sdlohserhTparTgnidaeReruliaF
41-12AR
61-12AR
mBd8-ot51-mBd11-mBd7-dnamBd51-mBd3-romBd81-
71-12AR
J1-12AR
mBd0ot5-mBd3-mBd0dnamBd6-mBd3+romBd9-
* Refer to the
Command Line Interface Reference Guide
,
NetBeacon Element Management Software Installation &
16User Guide
or
WebBeacon Management Software Installation & User Guide
for software management