User guide
Radiance T3/E3 Single Interface Line Cards 19
Technical Specifications
Network Connections
Coaxial Interface
Connector __________________________________________ BNC receptacle
Impedance________________________________________________ 75 ohms
Signal Structure ____________________________ ANSI T1.404, T1404a (T3)
_____________________________________ ITU G.703 (E3)
Supported Link Length ___________________________________ up to 1200 ft
Cable Type ______________________________________ RG-59 coaxial cable
Multimode Fiber Optic Interface
Connector ________________________________________________ ST or SC
Wavelength _______________________________________________ 1310 nm
RX Input Sensitivity ___________________________ -31 dBm peak minimum
Output Power _______________________ -20 dBm to -14 dBm (62.5/125 µm)
Supported Link Length ___________________________ up to 2 km full duplex
Cable Type __________________________________ 50/125, 62.5/125 µm F/O
Singlemode Fiber Optic Interface
Connector ________________________________________________ ST or SC
Wavelength _______________________________________________ 1310 nm
RX Input Sensitivity ___________________________ -31 dBm peak minimum
Output Power ___________________________ -15 dBm to -8 dBm (9/125 µm)
Supported Link Length __________________________ up to 15 km full duplex
Cable Type ______________________ 8.3/125, 8.7/125, 9/125, 10/125 µm F/O
Singlemode Fiber Optic Interface — long haul distance support
Connector _____________________________________________________ SC
Wavelength _______________________________________________ 1310 nm
RX Input Sensitivity ________________________________ -35 dBm minimum
Output Power _____________________________-5 dBm to 0 dBm (9/125 µm)
Supported Link Length __________________________ up to 40 km full duplex
Cable Type ______________________ 8.3/125, 8.7/125, 9/125, 10/125 µm F/O