User`s guide
6 Metrobility 10/100Mbps Delta Class AutoTwister
The unit may be oriented in any manner which allows you to make the
physical connection to the power supply and leaves a minimum of six (6)
inches of space for proper ventilation.
Wall Mounting
The AutoTwister requires no additional hardware for wall mounting. After
selecting an appropriate place for installation, simply align the 1/4"
keyhole opening on the bottom of the unit to a screw (6-32 maximum
head size) or wall anchor. Once you have it positioned properly, make
sure the device is attached securely.
Set the Switches
MDI-II/MDI-X Switch
To eliminate the need for crossover cables, the AutoTwister includes an
MDI-II/MDI-X switch on the copper port. This push-button switch is
located in the center of the front panel and enables either a straight-
through or crossover configuration.
100BASE-FX
10/100BASE-TX
II
x
MDI-II / MDI-X Switch
When setting the switch, note the position of the following symbols:
• The parallel symbol (II) indicates a straight-through or parallel
connection. Switch is out.
(default)
• The cross symbol (X) indicates a crossover connection. Switch is in.
Use the tables below as a guide.
A device that is wired straight through needs one crossover connection:
If the cable is
straight through
crossover
the MDI-II to MDI-X Switch Setting should be
X
II
A device that is wired crossover needs a parallel connection:
If the cable is
straight through
crossover
the MDI-II to MDI-X Switch Setting should be
II
X