User manual
Chapter II
32 VX0003 / VX0100
Category Appliance Household Office Precautions / Remedies
Safety
distance (in m)
Electric fields
Mains outlet
Low voltage electric utility company
transformer
x x Respect the safety distances 10
Cables and connections
50 Hz - permanent
Lighting Low consumption bulb x x
Earthed shield phase or two pole
switch
0,8
Switched mode power supply
10-50 kHz - permanent
Lighting 230 V halogen (on a stand...) x
Correct Ph/N connection or two pole
switch
0,6
Cables
50 Hz - permanent
Lighting
Low voltage decorative halogen or desk
lamp (transformer, wiring)
x x
Correct Ph/N connection or two pole
switch
1
Cables
50 Hz - permanent
Lighting Bedside or headboard lamp x
Correct Ph/N connection or two pole
Respect the safety distances
0,6
Cables and shielding
50 Hz - permanent
Lighting Ceiling lamp without earth x x
Correct Ph/N connection or two pole
Respect the safety distances
1,5
Cables and shielding
50 Hz - permanent
Lighting Compact fluorescent tube x x
Earthed shield phase or two pole
switch
0,8
Switched mode power supply
10-50 kHz - permanent
Building machinery
Lifts (machinery) x x Respect the safety distances 2
Cables and connections
50 Hz - permanent
Building machinery
Door (garage) or motorised curtain x
Transit areas (OK) or keep away from
rest areas
1
Cables
50 Hz - permanent
Electronic
equipment
Aquarium (lighting, pumps...) x x
Correct Ph/N connection
Away from rest areas
1,5
Cables
10-50 kHz switch-mode power supply