Operation Manual
Portable 4000 count digital multimeter 
23 
Range  4 kHz  40 kHz  400 kHz  4 MHz  40 MHz 
Caliber  0.005 - 4kHz 0.03 - 40kHz 0.2 - 400kHz 0.002-0.4MHz 0.02 - 0.4MHz 
Resolution  1 Hz  10 Hz  0.1 kHz  1 kHz  10 kHz 
Accuracy  0.1 % R ± 3 D 
Protection 600 Vrms
Sensitivity  200 mVrms  200 mVrms  1 Vrms  3 Vrms  3 Vrms 
Frequency band : 5 Hz ... 500 kHz 
4. G
ENERAL SPECIFICATIO
NS
• Mechanical features :
Dimensions : 170 x 80 x 35 mm 
Weight (with battery) : 285 g 
• Packing : Dimensions : 230 x 155 x 65 mm 
Weight : 385 g 
• Power supply :  1 battery 9 V (type 6LF22 or 6LR61)
 Battery life : approx. 200 hours with battery 6LR61 
 “ BAT ” :   battery discharge indicator 
• Buzzer : continuous beep for the continuity test 
intermittent beep each time the switch is operated 
or keys are pressed, and for overload indication 
Response time < 100 ms 
• Climatic conditions :
Reference temprature :  23°C ± 5°C 
Operating temperature :  0°C to 45°C 
Use temperature :  0°C to 50°C 
Storage Temperature :  -20°C to 60°C 
Relative humidity :  use  <
 80 % 
storage <
 95 % 
Protection rating :  IP 40 
• Safety : IEC 61010-1 
Insulation : class 2 
Pollution degree : 2 
Indoor use
Altitude < 2000 m 
CAT III, 600 V max. to earth 
• EMC : complies EN 61326-1 
5. A
CCESSO
RIES
5.1 
Accessories delivered with the multimeter 
1 set of test leads................................................................AG0475A 
1 battery 9 V (6LF22).............................................................AL0042 
1 fuse 10 A, 50 kA, HBC....................................................... AT0084 
1 fuse 0.63 A, 18 kA, HBC.................................................... AT0519 
1 protective elastomer case.............................................HX0002 (∗) 
1 user’s manual................................................................ 906129640 
(
∗
) version “ multimeter in a blister ”, only. 
5.2 Optional 
Protective elastomer case..................................................... HX0002 