Operating instructions

10/04/2015 67
POCLAIN HYDRAULICS Electronic mobile
Electronic control unitsElectronic componentsConnectorsCables Displays
Connector mounting
Strip the wires to a length of 5 mm [0.19 in].
Crimp the wires onto the pins as shown in the table below.
N° pin connector on SmartDrive™ CT controller Function N° pin male communication connector
Ground A
VBAT_P B
CAN 2 vehicle Connector B pin 10 CAN2 H C
Connector B pin 18 CAN2 L D
---E
---F
---G
CAN 1 diagnosis Connector B pin 1 CAN 1 H H
Connector B pin 2 CAN 1 L J
Overall dimensions
Receptacle: HD10-9-1939PE
Gasket: HD10-9-GKT
Cap: HDC9-JDL082397 Pin: 0460-202-1631
Stopper: 114017
Panel cutout
42,16 [1.66]
28,58
[1.12]
28,58
[1.12]
36,5 [1.44]
36,32 [1.43]
3,18
[0.13]
36,32 [1.43]
Ø 33,15
[1.31]
40,13 [1.58]
17,02
[0.67]
12,37
[0.49]
20,57 [0.81]
14,61 [0.57]
Ø 3,56
[0.14]
28,58±0,12
[1.12±0,005]
28,58±0,12
[1.12±0,005]
Ø 35,38±0,12
[1.39±0,005]
4x Ø 3,18±0,12
[0.12±0,005]
Maximum panel thickness: 6,35 mm [0.25 in]