Operating instructions
54 10/04/2015
 Electronic mobile  POCLAIN HYDRAULICS
Electrical connection
Pedal is delivered with a connection kit:
Counter connector kit includes: • Connector
• Terminals
• Wire seal
• Cavity plug
AMP ref. 1-967616-1 (x1)
AMP ref. 0-962885-5 (x7)
AMP ref. 0-0967067-1 (x7)
AMP ref. 967056-1 (x4)
To crimp correctly use:
 • Special crimping tool Tyco: 0-0539 635-1
 • Wire gauge: AWG20
 • External diameter of the wire: between1,29 mm and 1,6 mm
It is possible to connect a harness to use only 1 signal with connector Weather Pack: A51444S (for more details, see page 97).
It is possible to connect a harness to use 2 signals with connector Deutsch: A51445T (for more details, see page 98).
Layout
247 [9.72]
22°
30°
97 [3.82]
81 [3.19]
160 [6.30]
43,5 [1.71]
29
 [1.14]
95 [3.74]
80,5 [3.17]
89 [3.50]
69 [2.72]
I 8,4 [dia. 0.33] (3x)
70,5 [2.78]
49 [1.93]
24
[0.96]
I 6,8 [dia. 0.27] (4x)
I 9,7 [dia. 0.38]
M6 (4x)
M8 (4x)
25,9 [1.02 ]
+0,5
 0
+0.02
 0
30,4 [1.20 ]
+0,5
 0
+0.02
 0
17 
[0.67 ]
+0,3
 -0,2
+0.01
 -0.008
24 [0.94 ]
+0,4
 -0,5
+0.016
 -0.02
5,5
[0.22]
21,7 [0.85 ]
+0,1
 -0,2
+0.004
 -0.008
Tyco connector
Label