Operating instructions
38 10/04/2015
 Electronic mobile  POCLAIN HYDRAULICS
Layout Capteur G1/4 Capteur 9/16
Installation
For transmissions controlled by SmartDrive™ Easy Plus, Master and Premier System electronic control systems, this sensor 
may be fitted on a pump.
For other applications, please consult your Poclain hydraulics applications engineer.
Hydraulic connection
Connection O’ring
N.m [lb.ft] ± 10 %
9/16" - 18 UNF 2A Torique Ø11.98 x Ø1.98 [0.47 dia. x 0.08 dia.] 35 [25.8]
G 1/4" FPM 30 [22]
Observe the torques indicated.
Electrical connection Commercial name Part number
Cable for pressure sensor connection CABLE-PRESSURE-SENSOR-3M 003141105U page 93
When wiring, check that the wire can neither be cut off, nor torn off when the machine is 
working or moving.
Sensor side view Connector side view
A: Ground
B: 5 Vcc
C: Signal 0.5 to 4.5 V