Operating instructions
36 10/04/2015
 Electronic mobile  POCLAIN HYDRAULICS
Layout  M10 sensor G1/4 sensor
Installation
For transmissions controlled by SmartDrive™ Easy Plus, Master and Premier System electronic control systems, the sensor is 
fitted on brake valve VB 220. 2E0. 2F0 (See brochure No. A06604D).
For other applications, please consult your Poclain Hydraulics applications engineer.
Hydraulic connection
Nut O’ring FPM
N.m [lb.ft] ± 10 %
M 10 - 20 [14.75]
G 1/4" - 30 [22]
Observe the torques indicated.
Electrical connection Commercial name Part number
Cable for pressure sensor connection CABLE-PRESSURE-SENSOR-3M 003141105U page 93
When wiring, check that the wire can neither be cut off, nor torn off when the machine is 
working or moving.
Sensor side view Connector side view
A: Ground
B: 5 Vcc
C: Signal 0.5 to 4.5 V