Operating instructions

10/04/2015 15
POCLAIN HYDRAULICS Electronic mobile
Electronic control unitsElectronic componentsConnectorsCables Displays
DISPLAY 1.5
SD Display 1.5
Function
Displays informations (engine or pump RPM, pressure, error codes and
their designations...)
Part number A47449A
Features
Electrical data
DC power supply 9 to 60 V
Current consumption at 24 V <100 mA
Program flash memory 96 kB
EEPROM memory 64 kB
SRAM memory 3.3 kB
Screen Backlighted
Display type LCD, 2 x 8 characters
Keys 3 (illuminated)
Light indicators 3
Mechanical data
Operating temperature - 20 °C to + 70 °C [-4 °F to 158 °F]
Weight 63 g
Mounting Mounting hole
53 mm
Degree of protection IP 65 on the front; IP54 on the back
Interfaces/Protocols
CAN 1 (ISO 11898, 2.0B)
Layer 2, CANopen, J1939
D
Accessory
Commercial name
Part number
5 pin M12 cable CABLE-M12-180°-2000-5PT A19974L page 95
5 pin M12 120 Ohm cable CABLE-COM-M12-CAN-120 A25657N page 96
Layout
I52 [dia. 2.05]
I 60 [dia. 2.36]
57,9 [2.28]
1
2
3
4
5
10 [0.39]
40,9 [1.61]
5-pin M12 connector
1: Ground
2: VDC
3: CAN GND (internally connected to ground)
4: CAN H
5: CAN L
Top
Bottom
5-pin
M12 connector
View A
View A