11 SAFETY and ESD INFORMATION
11.1 Cellular Radio Safety
To comply with the FCC RF exposure limits and satisfy the categorical exclusion
requirements for mobile transmitters, the transmitter effective radiated power must be
less than 3.0 Watts ERP (4.9 Watts or 36.9dBm EIRP). This requires that the
combination of antenna gain and feed line loss does not exceed 16 dBi.
WARNING
This product contains a radio-frequency transmitter,
Motorola Model g18, FCC ID # IHDT6AC1 or
Motorola Model g20, FCC ID # IHDT56DB1.
The combined cable loss and antenna gain must not exceed 6.1dBi
gain, and the antenna installation must provide a minimum separation
distance of 20cm (8”) from users and nearby persons and must not
be collocated or operating in conjunction with any other antenna or
transmitter.
11.2 Hazardous Area Classification
At the time of this publication no hazardous area safety approvals have been received
for the DCM-200 product. It is therefore necessary to ensure that the product is only
installed at locations that are classified as ‘safe area’ sites. Safety barriers must be
utilized if it becomes necessary to route any cables into a hazardous area boundary.
Refer to the U.S. National Electrical Code (NEC) book, article 510, as well as any
relevant local ordnance for guidance with hazardous area wiring. It is the responsibility of
the user to ensure compliance with regulations regarding hazardous area locations. This
may require the site to be inspected by a certified electrician to maintain full compliance.
WARNING
No hazardous area safety approvals have been
received for this product.
It is therefore necessary to ensure that the product is only
installed at locations that are classified as ‘safe area’ sites.