6.3.3 “Slave Device” Checkbox
Checkmark this box if the ANSI device will using a DCM-200 to communicate with the
central computer. Seems obvious, but this screen is also used to configure an ANSI
device that has an internal modem for direct phone line communications.
6.3.4 “Master Device” List
If the “Slave Device Checkbox” has been checked, the Master Device box will be
highlighted. This is the device ID number of the DCM-200 that will be connected to this
meter. If the DCM-200 hasn’t yet been defined, pick any ID number from the list. It will
be updated automatically when the DCM-200 is configured.
6.3.5 Default User ID
This number must match the User ID number that has been programmed into the ANSI
meter using the manufacturer’s programming software.
6.3.6 Use Password or Encryption Key
This number must match the password or encryption value that has been programmed
into the ANSI meter using the manufacturer’s programming software.
Figure 6-9
Device ID Screen for the ANSI Device