User`s guide

12-1
12 TECHNICAL SPECIFICATIONS
Enclosure Dimensions (See Figures 2-2, 2-3 & 2-4)
Width: 6.91 inches (17.6 cm)
Height: 8.50 inches (21.6 cm)
Depth: 4.25 inches (10.8 cm)
Enclosure Mounting Pattern (See Figures 2-2, 2-3 & 2-4)
Width: 4.00 inches (10.2 cm)
Height: 8.94 inches (22.7 cm)
Max bolt size: 5/16 inch (7.5 mm)
DCM-200 Weight (with backup battery)
3.6 pounds (1.6 kg)
Backup Battery Pack
Type: Lithium in parallel with high-energy capacitor.
Voltage: 3.67V
Capacity: 1.1Ahr.
Model: Tadiran TLP-96111/A/S
Weight: 1.3 ounces (37 grams)
Retention life after 10 years: 85%
Power Supply Board Specifications
Input Voltage: Selectable 90 to 140 volts or 180-280 volts AC.
Line frequency: 50 or 60 Hertz.
AC burden: 6 watts with radio in the receive mode.
DC output voltage: 5.86 volts nominal at J3.
Maximum DC output current: 1.5 amperes.
Alarm signal: Active low = AC power present, open collector = AC power
failure.
LED indicator: Green LED illuminates when the power supply is
operating.
Fuse ratings: Install 2A slow-blow fuses at positions F1 & F2 for 12VAC.
(1001-0302 board) Install 2A slow-blow fuse at position F3 for 240 VAC.
Fuse type: 5x20mm. Littelfuse p/n 218-002 or equivalent.
Fuse ratings: 0.5A (500 mA) slow-blow fuse at position F1.
(1001-0310 board)
Fuse type: 5x20mm. Littelfuse 217-500 or equivalent