INTELLIGENT RACK MOUNT POWER DISTRIBUTION UNI T PR-R13PI OUTLET 12+1 1
Introduction Thank you for purchasing the PR-R13PI. Your new Power Distribution Unit (PDU) by Big Dog Power provides filtered AC power to your equipment. 12 individually controlled outlets provide up to 5100 Joules of surge Protection. Wi-Fi and Wired LAN connections allow for flexibility with placement and network connectivity. The built in Self-Healing functions of the PR-R13PI will keep your network connected equipment going by automatically resetting the power going to the outlet.
Features • 12 individually controlled outlets • 1 always on Front outlet • Rack Mountable 2U • • Self-Healing functions for network connected equipment Surge Mileage: Track when a Surge Event happens and the remaining health of the surge protection • Replaceable Surge modules • 2040 and 3060 Joule surge protection • Temperature monitoring with 4 thermostats • Web and Mobile app for remote management and notification • I/O for additional integrations • RS-232/Serial and IP automation inte
Big Dog Power™ by Metra Home Theatre, LLC Limited Product Warranty and Connected Equipment Limited Warranty Valid in the United States and Canada THIS WARRANTY DEFINES ETHEREAL HOME THEATRE. LLC’S LIABILITY FOR ANY AND ALL DAMAGES RESULTING FROM THE OPERATION OR FAILURE OF THE PRODUCT. THE WARRANTY PROVIDED IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, METRA DISCLAIMS ANY AND ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED.
Limited Product Warranty: Ethereal Home Theatre, LLC warrants this product to be free of material defects for a period of: (1) 5 years for the PR-R13PI, PRV7PI and PR-W3PI products, (2) 3 years for the PR-S1PI product, (3) PR-RMS1 and PRRMS2, replaceable surge modules carry a 90 Day warranty from manufacturing defects and (4) 3 years for any other product subject to this Warranty (referred to as the applicable “warranty period”).
For additional warranty information including Connected Equipment coverage and process visit us at metraav.com 6 PR-R13PI Connected Equipment Limited Warranty: This is a limited warranty, subject to the conditions, limitations and exclusions identified herein.
Anatomy A. B. C. D. Configurable Power Button LCD Display Display Navigation Buttons Replaceable Surge Modules S1 – 2040 Joule Rating S2 – 3060 Joule Rating E. USB Power Supply 2.4 amp 5v F. At a glance status LEDs See LED functions for more information G. Always On Service Outlet H H. I. J. K. L. M. Q. I/O 1x Contact Sensor Input 1x Relay Output R. Surface Mount Location for Rack Ears S.
LED Indicators “G” or Ground ON: PDU is grounded properly OFF: PDU is not grounded “P” or Power BLUE: Good / Protected and Clean power RED: Bad / No Protection “N” or Network BLINKING RED: No Network Connection SOLID BLUE: Good Network Connection RAPID BLINKING RED: PDU failure requires reboot or reset Outlet Status ON: Outlet is On OFF: Outlet is Off Voltage SOLID BLUE: Normal / Good Voltage SOLID RED: Over / Under Voltage Always On ON: Outlet is On OFF: Outlet is Off Surge Module ON: Good / Pro
Installation Installation Rack Mount 1. Use the included screws to attach the Rack Mount ears to the PDU near the face of the PDU 2. Slide the PDU into the rack where you intend to mount it 3. Secure the PDU using the appropriate screws for your rack Surface Mount 1. Use the included screws to attach the included Rack Mount ears to PDU at the secondary location You can find the secondary mount holes halfway towards the back of the PDU 2.
Installation Connections and Use Shelf Mount 1. Remove the protective film over the adhesive on the included Rubber Feet 2. Apply the Rubber feet to the bottom of the PDU 3. Slide the PDU onto shelf 4. Place PDU on Shelf Physical Connections 1. Screw in the Wi-Fi Antenna 2. Plug in all to be used connections Including: Ethernet LAN (Skip the Ethernet cable if you will be using Wi-Fi) Connected equipment power cables 3. Insert the female end of the included 6ft power cord into the PR-R13PI 4.
8. If required enter the password for the Wi-Fi connection 9. Click “Save” The PDU will now connect and reboot. After it has rebooted it will attempt to connect to the Wi-Fi signal. 10. Once the PDU has been connected to the network and has access to the web, proceed to the next steps Replaceable Surge Modules Remove 1. Firmly grasp the front top and bottom lip of the surge module 2.
Important Safety Instructions Read and observe the following safety points at all times. Notice For indoor use only. Internal components are not sealed from the environment. The device can only be used in a fixed location such as a telecommunication center, or a dedicated computer room. When you install the device, ensure that the protective earthing connection of the socket-outlet is verified by a skilled person.
questions about grounding, consult your local power company or a qualified electrician. This PDU requires a properly grounded outlet for safety. If you’re not sure if your home’s electrical wiring is properly grounded, have it checked by a qualified electrician. If a rooftop device such as a satellite dish connects to the PDU, ensure that the device’s wires are also properly grounded. Liquid: avoiding electrical shocks Do not operate the PDU if liquid of any kind is spilled onto or inside the unit.
• Consult the dealer or an experienced radio/TV technician for help. Notice: (1) An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord by used. (2) Use only shielded cables to connect I/O devices to this equipment. Note: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.
IC This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
INTELLIGENT POWER We’ve combined all of the features integrators need into one unique power distribution unit to deliver surge protection, remote control, smart home integration, rack temperature management, and more. The 12 individually controllable outlets have power metering, self-healing and automatic reboot capabilities for smarter remote management of your connected devices. An additional service outlet allows direct access for programming and setup without an Internet connection.