Specifications

38
01/2009 Rev. 2.0
5.2 Setting of the display to show cups or litres
The appliance is factory set to display the number of cups.
If you want the display to show litres, you can adjust it as follows:
1. Press the selection button (5.4) and hold it in, then press the start/stop button (5.5)
once. A number will appear in the display.
2. Release both the buttons and then press the start/stop button once again.
3. A“C”(Cups)willappearinthedisplay.Changethe“C”toan“L”withtheselection
button.
4. Now wait for 6 seconds. The adjustment has been saved.
5.3 Setting of the prewet function
This appliance can make coffee using two methods:
Continue-brew(“Cb”)(factorysetting);Thecoffeemakingprocessbeginsimmediately
and will
pourhotwateroverthegroundcoffeewithoutawaitingtime.Prewet-brew(“Pb”);partof
the
hot water is first poured onto the ground coffee. This causes the coffee to rise so that the
smells and flavours are released. The coffee making process then begins. If you want to
set the
appliance to Prewet brew, this setting can be changed as follows:
1. Press the selection button (5.4) and hold it in. Then press the start/stop button once.
A number will appear in the display.
2. Release both buttons and then press the start/stop button twice.
“Cb”(Continue-brew)willappearinthedisplay.
3. Usetheselectionbuttontochange“Cb”into“Pb”(Prewet-brew).
4. Now wait for 6 seconds. The adjustment has now been saved.
5.4 Setting the water temperature of the water boiler
On delivery the temperature of the water boiler is set at approx. 90 °C.
With the adjustment point (12.3) the temperature of the water boiler can be increased/
reducedwithinarangeof84–98˚C.Useasmallscrewdriverforthis.Toreducethe
temperature, turn left. To increase the temperature, turn right.
WARNING
• Inhighaltitudeareas(>2000metres.)thewaterwillboilsoonerbecauseoflower
atmospheric pressure. Adjust the temperature of the water boiler, so it will not boil.
• Themanufacturerisunabletoacceptanyliabilityfortheconsequencesofaltered
settings.