7 ALARMS LIST
1 THE FOLLOWING OPERATIONS SHOULD BE PERFORMED EXCLUSIVELY BY QUALIFIED AND AU-
THORISED PERSONNEL.
I IN CASE OF INCORRECT OPERATION, IT IS RECOMMENDED TO DISCONNECT THE MACHINE FROM
THE ELECTRICAL AND HYDRAULIC SUPPLY NETWORK.
The illuminated button has a combination of white and red colours, which indicate the operating or alarm status,
which are summarised below:
Signal / Alarm RED WHITE
(AL01) Alarm: cold cycle too long 1 x 0.5" 1 x 3.0"
(AL02) Alarm: cold cycles duration dierence 2 x 0.5" 1 x 3.0"
(AL03) Alarm: no water (if sensor present) 1 x 3.0" 1 x 0.5"
(AL04) Alarm: ice bin probe faulty 3 x 0.5" 1 x 3.0"
(AL05) Routine maintenance request ON 3" ON 3"
(AL06) High temperature at condenser outlet ON OFF
(AL07) Condenser probe alarm 4 x 0.5" 1 x 3.0"
(AL08) Evaporator probe (if present) 5 x 0.5" 1 x 3.0"
(AL09) Blackout - No power supply OFF x 1.0" 1 x 5.0"
(AL10) High pressure alarm ON OFF
(AL12) Long defrost alarm 6 x 0.5" 1 x 3.0"
(AL13) Capacitative sensor 1 x 3.0" 3 x 0.5"
(AL14) Condenser cleaning 7 x 0.5" 1 x 3.0"
(AL15) Probe reversal 5 x 0.5" 2 x 0.5"
(AL16) IR probe faulty 3 x 0.5" 1 x 3.0"
Download HACCP data and update SW 3 ash 3 ash
Machine start-up phase OFF 2Hz ash
Ice production phase OFF ON
Full bin OFF 10s ash
Standby OFF 30s ash
Ozone cycle phase OFF ON 1"
Gas lling phase (service) ON 1" ON 1"
OFF : LED / colour always OFF
ON : LED / colour always ON
ashing : LED / colour ON for 0.5s, OFF for 0.5s
•