7 LIST OF ALARMS
1 THE FOLLOWING OPERATIONS SHOULD BE PERFORMED EXCLUSIVELY BY QUALIFIED AND
AUTHORISED PERSONNEL.
I IN CASE OF INCORRECT OPERATION, IT IS RECOMMENDED TO DISCONNECT THE MACHINE
FROM THE ELECTRICAL AND HYDRAULIC SUPPLY NETWORK.
The illuminated button has a combination of white and red colours, which indicate the operating or alarm status,
which are summarised below:
Signal / Alarm RED WHITE
(AL01) Alarm: cold cycle too long 1 x 0.5" 1 x 3.0"
(AL02) Alarm: cold cycles duration di󰀨erence 2 x 0.5" 1 x 3.0"
(AL03) Alarm: no water (if sensor present) 1 x 3.0" 1 x 0.5"
(AL04) Alarm: ice bin probe faulty 3 x 0.5" 1 x 3.0"
(AL05) Routine maintenance request ON 3" ON 3"
(AL06) High temperature at condenser outlet ON OFF
(AL07) Condenser probe alarm 4 x 0.5" 1 x 3.0"
(AL08) Evaporator probe (if present) 5 x 0.5" 1 x 3.0"
(AL09) Blackout - No power supply OFF x 1.0" 1 x 5.0"
(AL10) High pressure alarm ON OFF
(AL11) Discharge pump alarm 1 x 0.5" 1 x 0.5"
(AL14) Condenser cleaning 7 x 0.5" 1 x 3.0"
(AL15) Probe reversal 5 x 0.5" 2 x 0.5"
(AL15) Probe reversal 5 x 0.5" 2 x 0.5"
(AL17) Evaporator High T. 1 x 3.0" 2 x 0.5"
Download HACCP data and update SW 3 ash 3 ash
Machine start-up phase OFF 2Hz ash
Ice production phase OFF ON
Full bin OFF 10s ash
Standby OFF 30s ash
Ozone cycle phase OFF ON 1"
Gas lling phase (service) ON 1" ON 1"
OFF : LED / colour always OFF
ON : LED / colour always ON
ashing : LED / colour ON for 0.5s, OFF for 0.5s