Owner's manual
Table Of Contents
- INDEX
- Bench Test 3
- Connections 3
- Keypad System 4
- Menu - Flow Chart 4
- Run 6
- Totalizer (Flow Mode) 6
- Password 6
- Units / Mode 7
- Flume Selection 9
- Calibration - for Level 10
- Calibration - for Open Channel Flow 11
- 4-20mA Current Loop Offset 12
- Rejection Time 12
- Relay Parameters 13
- Special Functions 15
- Sensor Location - Tank Level 17
- Sensor Mounting/Location - Open Channel 20
- Enclosure Installation 23
- Error/Warning Messages 24
- Field Troubleshooting 25
- Installation Considerations In Noisy Environments 27
- Customer Service 29
- Instrument Return Procedure 29
- Appendix A - Options 30
- Data Logger 32
- RS232C Serial Output 38
- Appendix B - Applications Background 41
- Conversion Guide 42
- Specifications 43
- Calibration Worksheet - Level Mode 46
- Calibration Worksheet - Flow Mode 47
- Units/Mode 1
- Warranty 1

Press È to Start (time) and Æ to position the cursor under the time column HH/MM/SS (24 hour
clock in Hours/minutes/seconds, eg:
23:02:16) and then È or Ç to set the logging start Time. Press
Æ to return to
Start .
Press È to Interval and Æ to the
Sec/Min column. Press È or Ç to set the logging time interval.
Choose:
30 Sec
10 Sec
5 Sec
2 Sec
1 Sec
30 Min
10 Min
5 Min
2 Min
1 Min
Press Æ to return to to Interval and È to Reset Log? To erase all existing data in the log press Æ
to
Yes and È. To keep existing data in the Log press È from Reset Log? If you have made changes
to the Start Date, Time or Interval, the data logger will automatically start a new “session”. The Ultrason
will display “
xxxxx Hrs/Days Left”.
From the
xxxxx Hrs Left display press È to Store? Yes. Press Æ to Yes and then È to save your
Data Logging setup, or press È from
Store? to cancel changes made above and exit without storing
changes.
From the Data Logging
Store? Yes prompt the menu will return to RUN STOP SETUP. Press Æ to
position the cursor under
RUN and press È to activate the Data Logger to start at your selected start Date
and Time. The Ultrason will display
SESSION NO. x. Press È to return to DATA LOGGING.
‘Event’ based Trend Logging
Event based logging stores data points only when a High or Low flow set point has been reached.
With cursor under
Event press È to HiAlm LoAlm . HiAlm will log points above a selectable flow
rate, while
LoAlm will log points below a selectable flow rate. Position the cursor under HiAlm or
LoAlm and press È to the At: prompt. Press Æ to the numerals column and press È or Ç to set flow
alarm logging set point. Press Æ to return to
At:
AquaMetrix
Ultrason
Page 36