Specifications

16
Resistance
Range
1
Accuracy
2
600.0 ±(2.0%+6 dgt)
6.000 k ±(1.2%+6 dgt)
60.00 K, 600.0 K ±(1.0%+4 dgt)
6.000 M ±(2.0%+4 dgt)
Open Circuit Voltage: 0.4VDC typical
1)AutoTect is for 6.000k ~ 6.000M ranges;
2)Add 40 dgt to specified accuracy while reading is below 20% of
range
Frequency
Range
1
Accuracy Specified At
10.00 Hz -30.00 kHz
2
< 2 0 V Sine-rms
10.00 Hz -999.9 Hz
±(0.5%+4 dgt)
< 600 V Sine-rms
1
Sensitivity (Sine-rms):
Hz in Auto-V position:> 3 V
2
Line-level Hz in V position
@ 6.000 V ac range: > 3 V
@ 60.00 V ac range: > 6 V
@ 600.0 V ac range: > 60 V