User's Manual
PRELIMINARY
FCC ID: BIB61201001
INTALLATION 3-15
PRELIMINARY
MCC-6120 SDR Packet Data Radio Network
Always check with your System Administrator to determine which device type your unit should
be configured as.
For example, if the device should be a Remote Station and it is not currently configured properly,
you can change the device type, as follows:
DEVICE,REMOTE [ENTER]
SAVE [ENTER]
CAUTION
Do not change the device type unless told to do so by your System Administrator.
Changing the device type can make your unit cease operating and can impact
communications throughout the entire network.
3.3.3.2 Verify ID Number
Every MCC unit is programmed at the factory with a 16-bit unit ID. To display the unit ID
number on the operator terminal, enter:
ID [ENTER]
Contact your System Administrator to make sure this ID is registered in the network
configuration database. Under some circumstances the ID may have to be changed on-site. This
can only be done if the ID is not locked.
CAUTION
ID changes must be coordinated with both MCC and your System Administrator. Failure
to do so may result in data or messages being misrouted or lost.
If the site is equipped with a CIM (Configuration Information Module), the ID for the
MCC-6120 will be set from the CIM.
3.3.3.3 Verify Channel Frequency
The MCC-6120 SDR is programmed at the factory with the authorized frequencies to be used on
a specific channel in your network. These channels and frequencies are stored in Parameter
memory and cannot be changed. Verify that the correct channel and frequency is configured by
entering the command:
CHANNEL [ENTER]
or CHAN [ENTER] for short cut