Operating Manual

PRELIMINARY
FCC ID: BIB61201001
INTALLATION 3-14
PRELIMINARY
MCC-6120 SDR Packet Data Radio Network
At this time all configuration data is loaded from Program Memory into RAM. This data will
remain in RAM until power cycled.
This is the type of message that should be displayed when you first apply power to the unit
during a field installation, and for each subsequent power cycle of the radio.
After power is applied to the radio all parameters that were entered and saved during the
previous session will be reloaded from Flash2 memory.
If you want to load factory defaults, power cycle the unit while holding the lower case f key
down. After about 10-15 f’s are displayed, release the key and you should see the following
message:
+fffffffffffffffffffffffffff
Ver 1.0
SDR Boot... (Entry due to operator request)
1.. Factory Default
9.. Launch Application
Enter a 1 followed by carriage return to restart with factory default parameters.
Enter a 9 to restart the application without changing the stored parameters.
If you restart with factory defaults, the proper script file must be re-entered into the MCC-6120
SDR using XTERMW. (Refer to Section 3.3.3.5 for more information on using script files.)
If you do not have a script file to load you can go through the following procedure to manually
start the unit.
3.3.3 Initialization Procedures
The following initialization procedures should now be performed in the order they are given
below.
3.3.3.1 Verify Device Type
The MCC-6120 SDR must be programmed to operate as a particular device type, such as Remote
Station, Repeater, or Base, depending on your network configuration. The device type is
normally set at the factory prior to shipment to ensure proper integration with your network.
Use the following command to display what device type the unit is configured as:
DEVICE [ENTER]