Operations Manual

OPERATIONS 4-43
O&M of the MCC-545B PACKET DATA RADIO
12/2000
†CORPAT,RX,action
{,pppp...}
Define Receiver correlation patterns to recognize.
Pattern 1 is the default and is the only pattern recognized
if no others specified. Up to 16 pre-defined patterns are
recognized.
action = ON
define patterns
or
OFF – use only
default pattern
pppp = pattern
number; ALL
means
recognize all
patterns
1 – 8
†CORPAT,TX,pppp
{,ALWAYS}
Define Transmitter correlation pattern to send. Pattern 1
is the default and is the only pattern recognized if no
other specified. Up to 16 pre-defined patterns may be
used.
pppp = pattern
number
ALWAYS means
use specified
pattern instead
of received
pattern
1-- 8
CR10X
Display CR10X configuration parameters
CR10X,ACQMODE,mo
de
Set CR10X acquisition mode - Get all reports since last
UPDT
mode =
ALL – get all
reports since last
update
CURRENT
get only the
current data
report
LAST,n – get
lastn data
reports