Operations Manual

OPERATIONS 4-8
O&M of the MCC-545B PACKET DATA RADIO
12/2000
The command MONOFF turns off the burst monitor.
4.2.5 Controlling the Hourly Statistics Report
By default, an hourly statistics report is generated on the maintenance terminal port on the hour.
This report consists of the same statistics reports generated by the BINS, MEM, and STAT
commands.
The hourly report can be disabled by entering the command:
HOURLIES,OFF
The hourly report can be re-enabled by entering the command:
HOURLIES,ON
4.2.6 Scheduling 545B Events
The 545B SCHED command allows you to schedule automated command "events". An "event"
simply consists giving one or more 545B commands a trigger time. When the 545B's real-time
clock reaches the trigger time, the scheduler invokes the command as though you had entered it
from the 545B's operator terminal.
Two different types of time trigger options are provided for command scheduling: INTERVAL
and TIME. The INTERVAL trigger allows you to schedule a command to be invoked at periodic
intervals within a 24-hour time period; the TIME trigger allows you to schedule a command to
be invoked only once at a specified point within a 24 hour time period. The command schedule
list is restarted each time the real-time clock reaches midnight.
To display current schedule list, enter:
SCHED
To add a new command to the schedule list, enter:
SCHED,type,time{OFFSET,time},command
where: type = INTERVAL or TIME
time = hours:minutes:seconds
OFFSET,hh:mm:ss = time offset from specified timeframe (optional)
command = any 545B command (with parameters)