Table 4.1 shows the roles for which an MCC-545C can be configured; this is just an overview of the general commands
needed for each role. The MCC-545C is not normally used in a Meteor Burst-only type of network.
Appendix F contains a description of the interoperability of all three types of MCC networks.
Table 6: Role-based operations
LOS Network
Base and Repeater Stations
Remote/Mobile units
LOS Network
Multiple Master Stations
Remote Stations (fixed or mobile)
Meteor Burst Network
Single Master Station
Remote Stations (fixed)
ROLE,LOS
ROLE,LOS ROLE,TRANSPOND
DEVICE,BASE
DEVICE,REPEATER,id (which Base or
Repeater to report to)
DEVICE,REMOTE
DEVICE,MASTER
DEVICE,REMOTE
DEVICE,REMOTE
For Base/Repeaters:
ID,master id
For Remotes:
ID,remote id, master
id,AUTO
For Masters:
ID,master id
For Remotes:
ID,remote id, master id
For Masters:
ID,master id
For Remotes (single Master):
ID,remote id, master id
For Remotes (multiple Masters):
ID,remote id,1,MULTI,INIT
P,t
(idle probe rate – typically t=20
seconds for Base and Repeaters; set
t=OFF for Remotes in an LOS network)
P,t
(idle probe rate
typically
t=
20
seconds for Base and Repeaters; set
t=OFF for Remotes in an LOS network)
P,OFF
(for Remotes)
BASE,low id,hi id (typically 2-230 –
used as a switch that turns the
Base/Repeater mode on)
BASE,OFF
(BASE command not used in a Meteor
Burst network)
CONNECT, master id1, master id2
(limits which Master(s) a Remote Station
can communicate with)
CONNECT, master id1, master id2
(limits which Master(s) a Remote Station
or Master Station can communicate with)
(CONNECT command not used in a Meteor
Burst network)
SNP,NDOWN,2,10 (Remotes switch to
SNP,NDOWN,120,10
(Remotes switch to
(Single Master Station networks use