configuration parameters as the MCC-545C Operator Port. The Operator
Port of the MCC-545C has the following factory default configuration:
Baud rate
9600
Data bits
8
Stop bit
1
Parity
no
Protocol
ASCII
Flow control
none
5.1.2 HELP Command
Entering HELP [ENTER] displays all of the commands used in the
operation and maintenance of the MCC-545C. To obtain descriptive
information about a particular command and how it is used by the MCC-
545C, enter the command type. For example: HELP, ASSIGN [ENTER].
Refer to the last section of this chapter for a complete list of MCC-545C
commands.
5.1.3 Role-Based Operations
The role that the MCC-545C plays in a communications network
determines how it should be configured. There are three basic roles
that an MCC-545C can be used in, depending on the network type:
• LOS Network consisting of Base and Repeater Stations, and
Remote/Mobile units; Base Stations do not communicate with each
other in this type of network. This is a typical FleetTrak™ network.
• LOS Network consisting of one or more Master Stations and Remote
Stations (either fixed position or mobile units); Master Stations can
communicate with each other in this type of network. This is a
typical DataNet network.
• Meteor Burst network consisting of a single Master Station
communicating with Remote Stations in fixed positions; Remote
Stations do not communicate with each other in this type of
network. This is a typical Meteor Burst network.