User's Manual
545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
© 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute. 35
When power applied is initially applied to the MCC-545C, or after a
software boot or hardware reset, the following message will be
displayed:
545C PACKET DATA RADIO
(c) Copyright 2005 Meteor Communications Corp.
All Rights Reserved
S/W Part Number* P1079-00-00 Version* 6.87 09/29/05
* Part Number, Version Number, and date vary according to a particular
radio’s firmware.
At this time all configuration data is loaded from Program Memory into
RAM. This data will remain in RAM and on all subsequent power-cycle
sequences the following message will be displayed:
01/23/04 16:54:10 POWER SHUTDOWN/FAIL OCCURRED.
02/02/04 12:54:44 POWER HAS BEEN RESTORED... RESUMING OPERATION.
+
This is the type of message that should be displayed when you first
apply power to the unit during a field installation, and for each
subsequent power cycle of the radio.
If the greeting message is not displayed, then the RAM contents may
have been lost under one of the conditions described in Section 2.4 and
the proper script file must be re-entered into the MCC-545C using
XTermW. (Refer to Sections 3.3.3.5 and 4.2.7 and Appendix C for more
information on using script files.)
4.3.3 Initialization Procedures
The following initialization procedures should now be performed in the
order they are given below.
Verify Device Type
The MCC-545C must be programmed to operate as a particular device
type, such as Remote Station, Repeater, or Base, depending on your
network configuration. The device type is normally set at the factory
prior to shipment to ensure proper integration with your network.