User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
© 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute. 19
The RAM contents will be lost under the following conditions:
The Boot command is issued.
The Reset button (SW1) is depressed. (Remove the rear panel to
locate SW 1.)
The internal backup battery fails or is disconnected. (In -02 units,
remove jumper JP1 while the external power is turned off to the
unit. In -03 or later units, remove connector J1.)
The watchdog timer initiates a restart.
The software will detect these events and will recopy the parameters
and configuration values from Parameter memory back into RAM when
operation is resumed.
If the contents of Parameter memory become invalid the unit will revert
to the factory defaults in Program memory.
3.8 Front Panel LEDs
The two LEDs on the front panel provide the operator with a quick
assessment of the unit’s operational status.
Figure 6: MCC-545C front panel LEDs
LED COLOR STATUS
ON
Green; flashes every 5 seconds
Power is on and the processor is running
TX
ON LED