User's Manual
545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
18 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
Switches: SW1
System Reset, Momentary
3.7 Memory Organization
The MCC-545C has three types of memory:
3.7.1 Program Memory (PM)
The Program memory is non-volatile Flash (512K x 16). It contains the
MBNET200 image software, bootstrap, configuration, and application
software. These programs are installed at the MCC facilities at the time
of shipment. The information stored in the Program memory is referred
to as “factory defaults”.
3.7.2 Parameter Memory (CPM)
The Parameter memory is non-volatile Flash (512K x 16). It contains the
configuration data for the unit such as the customer number, the serial
number and ID of the MCC-545C, and the authorized FCC frequencies it
may use. This information is normally programmed into the unit prior to
shipment. The Script files are also stored in Parameter memory, either
at the MCC facilities or on site.
3.7.3 Data Memory (RAM)
The Data memory is volatile RAM (1024K x 8) and has battery backup.
Date, time, executable programs, command parameters, and program
dynamic data (messages, data, position, etc.) are all stored in RAM
during normal operations. As an option, the Data memory may be
expanded to 2048K x 8.
During normal operation, the MCC-545C software uses the data and
configuration parameters stored in RAM. If the data information in RAM
is lost or corrupted, for whatever reason, the configuration parameters
can be retrieved from Parameter memory. This ensures uninterrupted
operation.