3.6 Detailed Specifications
The detailed specifications for each of the printed circuit board
assemblies are given in Tables 2.1 through 2.4.
Table 1:MCC-545C general specifications
Characteristic Specification
Dimensions
10.6"L x 4.0"W x 2.42"H
Weight
3.5 lbs.
Temperature Range
-
30
°
to 60
°
C (
-
22
°
to 140
°
F)
Power Requirements
12 V
DC
Nominal (10
-
14 V
DC
)
Standby: 80 ma (Continuous)
Transmit: 25 Amps Nominal (100 msec)
Table 2:MCC-545C receiver specifications
Characteristic Specification
Frequency
37
-
50 MHz
or 43
-
46 MHz
Synthesized 10 kHz steps
Frequency accuracy, calibrated: ±1ppm
Frequency stability: ±5ppm -30°to +60°C
Modulation: Type
Rate
Format
GMSK
9.6 kbps
NRZ
Noise Figure
7
dB
Sensitivity: Bit Error Rate < 10
-
3
at 9.6
kbps
-
114
dBm
IF Bandwidth (3/80 dB)
13/40 kHz typical
RF Bandwidth (3 dB)
13 MHz typical
Signal Acquisition Time
< 5 ms
3
rd
Order Intercept Point
>
-
4 dBm
Image Response Attenuation
> 70 dB minimum
Spurious Response Attenuation
> 70 dB minimum
SP Threshold
Adjustable from
115 to
106 dBm
Triggered by DET RF and Demodulator
Lock
Noise Blanker
> 20 dB Reduction in Impulse Noise