User's Manual
545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
© 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute. 185
COMMAND DESCRIPTION PARAMETERS RANGE
†SUBST,rrr,g1,nnn,g2 Substitute Remote unit information in data
reports received from a relay unit.
rrr = relay ID
g1 = relay grp#
nnnn = Remote ID
g2 = Remote grp#
1 – 245
0 – 15
256 – 4095
1 – 4
†SUBST,DEL,ALL Delete entire substitution table
†SUBST,DEL,rrr,g1 Delete entry in substitution table rrr = relay ID
g1 = relay grp#
1 – 245
0 – 15
†SWCTL,OFF Disables the monitoring and switching function.
†SWCTL,ON,
timeout
,
start
delay
When the software boots up from a reset state,
it will test the two RS-232 ports to determine
which one is currently active, assuming the
switch may have been manually controlled while
it was off. From then on, it monitors the two
Masters assuming the primary Master (1) is
connected to the DTA port, and the Secondary
Master (2) is connected to the ALT port.
timeout = inactivity time in
seconds resulting in
switchover.
start delay = interval in
seconds after starting
before monitoring Master
Stations.
1 – 32767
1 - 32767
SWCTL,SW,n Switch to designated Master Station switch
position.
n = switch position 1 - 2