COMMAND DESCRIPTION PARAMETERS RANGE
†STATION TYPE{,aaaaa} Display/set special Station functionality.
Determines how each Station responds to the
messages it receives and limits the type of
messages that can be created. Meaningful only
in Flood Warning and Maritime Weather
Systems.
aaaaa =
OFF
FLOOD BASE
FLOOD WARNING
GLOF SENSOR
GLOF MONITOR
GLOF WARNING
RELAY
STREAM GAUGE
SYSTEM MONITOR
WEATHER
†STOP Turn transmitter off.
†STT,secs Set command timeout (in seconds). Default is 15
seconds.
secs = time limit before reset
(0-off, >0-on)