User's Manual
545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
178 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
COMMAND DESCRIPTION PARAMETERS RANGE
†SCHED{,basis,hh:mm:ss
{,OFFSET,hh:mm:ss},
command string}
IMPORTANT
SCHED ignores the MESSAGE
command. Up to 50 events
can be scheduled.
Schedule execution of the specified command
string. If timeframe basis = INTERVAL, the
command string will be executed whenever the
specified time interval elapses during the day. If
timeframe basis = TIME, the command string will
be executed at the specified time. The OFFSET
option allows specification of an offset from the
timeframe basis.
basis =
TIME
or
INTERVAL
hh - hours
mm - minutes
ss - seconds
0 – 23
0 – 59
0 – 59
†SCHED,DEL,nn Delete specified schedule item number. If nn =
ALL, the entire schedule will be cleared.
nn = schedule item number
1 – 50
SDATA,g,c,time stamp,
value...
Enter an MCC-550C data report directly from the
serial I/O port. Up to 16 values may be entered.
Use the LINK command to route the data.
g = group number
c = sensor count
time stamp = mmdddhhmn
value = ASCII hex sensor
value
1 – 4
1 – 16
mm 1 – 12
ddd 1 –365
hh 0 – 23
mn 0 – 59
0 – FFFF